Product Details

Product Description

The Allen Bradley 2711-K5A5 belongs to the PanelView 550 standard operator terminal series, designed for industrial environments requiring reliable keypad-based input. This model features a compact 5.5-inch monochrome LCD display with transflective technology, ensuring visibility under varying lighting conditions. With rugged enclosure ratings and long-life LED backlighting, it provides durability and consistent performance in demanding applications.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: PanelView 550

  • Category: Standard Operator Terminals

  • Model / Part Number: 2711-K5A5

  • Weight: 3 lbs (1.36 kg)

  • Display Size: 5.5 inches

  • Display Area: 120 × 60 mm (4.75 × 2.38 in.)

  • Display Type: Monochrome transflective LCD with LED backlight

  • Display Color: Blue mode monochrome

  • Resolution: 256 × 128 pixels

  • Backlight Life: 100,000 hours (LED)

  • Operator Input: Keypad with 10 function keys (F1–F10)

  • Application Memory: 170 KB runtime; 240 KB nonvolatile storage (objects, text, bitmaps)

  • Communication Ports: RS-232 (DH-485 protocol)

  • Communication Cable: 2711-NC13

  • Input Voltage Range: 85–264 VAC

  • Input Frequency: 47–63 Hz

  • Input Power: 120 VAC nominal

  • Enclosure Ratings: NEMA Type 12/13, 4X (indoor use), IP54, IP65

  • Status Indicators: Green COMM LED, Red Fault LED

  • Series Versions: A, B, C, D, E, F, G, H

  • Lifecycle Status: Discontinued / Obsolete

Application Scenarios

The 2711-K5A5 is suitable for machine-level control, operator interface tasks, and monitoring applications where keypad input is preferred over touchscreens. Its rugged enclosure makes it appropriate for indoor industrial use with protection against dust and water spray.

FAQ

Q: What type of input does this terminal support?  A: It uses a keypad with 10 function keys (F1–F10).

Q: Is the backlight replaceable?  A: No, the LED backlight is integrated but rated for 100,000 hours of operation.

Q: What communication protocol is supported?  A: The terminal communicates via RS-232 using the DH-485 protocol.

Q: What is the enclosure rating?  A: It meets NEMA Type 12/13, 4X (indoor), IP54, and IP65 standards.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more