Only 10 left - Selling fast

PRODUCT SKU : 22B-D012N104

PRODUCT TYPE : Adjustable Frequency AC Drive

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 22B-D012N104 represents a powerhouse within the PowerFlex 40 family, specifically engineered for sophisticated motor speed control and high-demand torque applications. This Variable Frequency Drive (VFD) manages a 5.5 kW (7.5 HP) output, delivering precision speed regulation for conveyors, fans, and pumps. We provide this unit as 100% Brand New and Factory Original, ensuring your facility avoids the high failure rates associated with refurbished power electronics.

Technical Specifications

The 22B-D012N104 utilizes high-grade semiconductors and advanced control algorithms to maintain performance across its 12-Amp rating:

Feature Specification
Series PowerFlex 40
Voltage Input 480 VAC, 3-Phase
Output Current 12 Amps
Power Rating 5.5 kW / 7.5 HP
Enclosure Rating IP20 / NEMA Type Open (Panel Mount)
Control Interface Fixed Keypad (Integrated HIM)
Dynamic Braking Standard Brake IGBT Included
EMC Filter Not Filtered
Net Weight 17.64 lbs (8.0 kg)

Engineering Advantages

  • Zero-Stack™ Mounting Efficiency: The PowerFlex 40 design allows side-by-side mounting without clearance gaps. This reduces cabinet footprint requirements by up to 30%, solving the industrial pain point of overcrowded control panels.

  • Sensorless Vector Control: This drive utilizes sophisticated algorithms to provide high torque across a wide speed range. It compensates for load fluctuations instantly, maintaining consistent shaft speed without the need for external encoder feedback.

  • Integrated Dynamic Braking: The built-in brake IGBT allows for direct connection of a braking resistor. This feature enables rapid deceleration of high-inertia loads and prevents "overvoltage" faults during aggressive stopping cycles.

  • StepLogic™ Programming: The 22B-D012N104 supports basic logic functions directly on the drive. This allows the inverter to operate as an independent controller for simple sequencing tasks, offloading processing strain from the central PLC.

FAQs

  • Is this 22B-D012N104 drive a brand new unit?

    Absolutely. We supply only 100% Brand New hardware in its original Allen Bradley packaging. We do not sell used, repaired, or "pull-off" drives, guaranteeing full service life and factory-spec performance.

  • How do I handle the "Not Filtered" emission status?

    Because this model lacks an internal EMC filter, you should install an external line reactor or RFI filter if your application resides in a noise-sensitive environment. This prevents high-frequency harmonics from interfering with nearby sensors or communication lines.

  • Can this drive replace a PowerFlex 4 model?

    Yes. The PowerFlex 40 (22B series) serves as an enhanced version of the PowerFlex 4. It offers expanded I/O and better control features while maintaining a similar physical profile, making it a viable upgrade for most 480V applications.

  • What are the cooling requirements for IP20 panel mounting?

    The IP20 NEMA Open rating requires installation within a protective enclosure. Ensure your cabinet provides sufficient airflow or active cooling to maintain an ambient temperature below 50°C (122°F) to prevent thermal derating.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more