Skip to content

What are you looking for?


You may also like

20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module
20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module
20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module
20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module

20-HIM-C6S | Allen Bradley PowerFlex Enhanced Human Interface Module


Only 10 left - Selling fast

PRODUCT SKU : 20-HIM-C6S

PRODUCT TYPE : Human Interface Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 20-HIM-C6S serves as an enhanced Human Interface Module (HIM) designed for the PowerFlex® architecture class of AC and DC drives. This remote-mount terminal provides a high-visibility LCD and a full numeric keypad for advanced programming, real-time monitoring, and rapid troubleshooting of motor control systems. We supply this unit as 100% brand new and original, complete with the necessary interface cable for immediate integration into your industrial control network.

Technical Specifications

The 20-HIM-C6S provides a ruggedized interface for demanding plant-floor environments:

Feature Specification
Product Type Enhanced Human Interface Module (HIM)
Display Type Multilingual LCD
Keypad Type Full Numeric
Enclosure Rating IP66, UL Type 4X / NEMA Type 12 (Indoor Use Only)
Operating Voltage 12V DC (Sourced from Host Drive)
Current Draw 140 mA
Included Accessories 1202-C30 Interface Cable (3 meters)
Compatibility PowerFlex 70, 700, 750 Series, SMC Flex, SMC 50
Weight 1.06 lbs (0.48 kg)
UPC 820919959974

Engineering Advantages

  • Ruggedized Remote Access: The IP66 and NEMA 4X/12 rating allows engineers to mount the 20-HIM-C6S on the exterior of an enclosure. This setup enables operators to program and monitor drives without opening the cabinet door, maintaining arc flash safety boundaries.

  • Comprehensive Multi-Drive Support: A single 20-HIM-C6S interface works across a vast range of Rockwell Automation hardware, including the PowerFlex 750-class and SMC soft starters. This versatility reduces the need for multiple specialized programming tools in your spare parts inventory.

  • Enhanced Data Visualization: The high-resolution LCD displays parameters in plain text rather than cryptic codes. It features a status bar with DeviceLogix™ indicators and improved soft-key labels (ACK, PGDN, PGUP) for intuitive menu navigation.

  • Full Numeric Entry: The full numeric keypad facilitates rapid parameter changes and setpoint adjustments, significantly outperforming standard up/down arrow interfaces during large-scale system commissioning.

  • Plug-and-Play Connectivity: The module includes a 3-meter 1202-C30 connection cable. The drive automatically recognizes the HIM upon connection, enabling immediate access to diagnostics and configuration menus without requiring secondary software.

FAQs

  • Can I use the 20-HIM-C6S for outdoor applications?

    No. While the IP66 and NEMA 4X ratings provide superior protection against dust and high-pressure water jets, the manufacturer specifies this module for Indoor Use Only.

  • Does this module support hot-swapping?

    Yes. You can connect or disconnect the 20-HIM-C6S from the drive's DPI port while the system is powered on, allowing maintenance teams to move a single HIM between multiple drive cabinets for periodic status checks.

  • Is this a genuine Allen Bradley original part?

    Absolutely. We guarantee that every 20-HIM-C6S we ship is 100% brand new in original factory packaging. It carries the verified UPC (820919959974) and meets all E-E-A-T industrial procurement standards.

  • What is the purpose of the included 1202-C30 cable?

    The 1202-C30 is a 3-meter (9.8 ft) male-to-male DPI cable. It bridges the communication between the drive's internal port and the remote-mounted HIM, providing both data transfer and operating power to the module.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more