Skip to content

What are you looking for?


You may also like

20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module
20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module
20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module
20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module

20-750-S | Allen-Bradley | PowerFlex 750-Series Safe Torque Off (STO) Option Module


Only 10 left - Selling fast

PRODUCT SKU : 20-750-S

PRODUCT TYPE : Drive Safety Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 20-750-S functions as a critical safety component within the PowerFlex 750-Series (PowerFlex 753 and 755) drive architecture. This hardware-based Safe Torque Off (STO) option module provides a dedicated solution for removing rotational power from the motor without disconnecting the drive from the main power source. We supply this unit as 100% Brand New original factory stock, enabling engineers to meet stringent global safety certifications while maintaining high system availability and reducing mechanical wear on line contactors.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line PowerFlex 750-Series Options
Part Number 20-750-S
Safety Function Hardwired Safe Torque Off (STO)
Safety Ratings SIL3 (IEC 61508), PLe (ISO 13849-1), Cat 4
Input Voltage 24V DC Safety Inputs
Compatibility PowerFlex 753 and PowerFlex 755 (All Frames)
Mounting Dedicated Internal Option Slot
Response Time < 12 ms (Typical)
Weight 0.28 lbs (0.13 kg)

Engineering Advantages

  • Certified Functional Safety: The 20-750-S meets the highest safety integrity levels, including SIL3, PLe, and Category 4. This certification allows the module to serve as the primary safety interface in high-risk applications such as robotic cells, web handling, and heavy material transport.

  • Elimination of Line Contactors: By utilizing the STO function, the drive stays energized while the motor remains in a safe, torque-free state. This removes the need for expensive and bulky redundant line contactors, significantly reducing cabinet space and eliminating the arcing/wear associated with cycling main power.

  • Rapid Restart Capability: Since the drive logic remains powered during an STO event, the system resumes operation immediately once the safety circuit clears. This minimizes downtime compared to traditional "E-Stop" methods that require a full drive reboot and communication handshake.

  • Hardwired Reliability: The module features redundant 24V DC safety inputs. This dual-channel architecture ensures that a single component failure within the safety string will not result in a loss of the safety function, providing a fail-safe environment for plant personnel.

  • Simplified Integration: The 20-750-S snaps directly into the drive’s internal option ports. Pluggable terminal blocks facilitate fast wiring and allow for quick module swaps during preventive maintenance cycles without disturbing the field cabling.

FAQs

  • Can I use the 20-750-S for a "Safe Stop 1" (SS1) function?

    The 20-750-S provides an immediate "Safe Torque Off" (Category 0 Stop). To achieve an SS1 (timed or monitored deceleration), you must combine this module with an external safety relay (like a Guardmaster Minotaur) to manage the deceleration ramp before triggering the STO.

  • Does this module support Safety over EtherNet/IP?

    No. The 20-750-S is a hardwired safety module. If your application requires networked safety (CIP Safety), you must utilize the 20-750-S3 (Integrated Safety) or 20-750-S4 (Integrated Safety Functions) modules.

  • Is the 20-750-S compatible with both PowerFlex 753 and 755?

    Yes. It maintains full hardware compatibility across the entire PowerFlex 750-Series family, regardless of the frame size.

  • How do I confirm the safety integrity of a new unit?

    Every 100% Brand New 20-750-S we ship comes in original, factory-sealed anti-static packaging with a verifiable serial number and manufacturer's Certificate of Conformity to ensure it meets all stated safety ratings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Batch vs Continuous Processing in Industrial Automation: Architectural Strategies for Control Engineers

Selecting the proper control architecture remains a pivotal decision when designing industrial automation systems. Automation engineers must evaluate whether a batch or continuous process model best fits their production requirements. This fundamental choice influences PLC and DCS programming, hardware redundancy, sensor selection, and overall factory automation layouts.

Read more
Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Demystifying Signal Isolators: Operating Principles, Architectural Types, and Industrial Applications

Industrial automation systems rely on pristine analog signal transmission across complex control loops. Instrument technicians and system integrators frequently deploy signal isolators to maintain signal integrity between field sensors and control platforms. Eliminating electrical noise, ground loops, and high-voltage transients protects delicate PLC, DCS, and SCADA input channels from permanent damage.

Read more
Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Demystifying Industrial Control Systems: Comparing PLC, DCS, RTU, SCADA, and PAC

Modern factory automation relies on distinct control architectures to manage complex process environments efficiently. Control engineers often evaluate PLC, DCS, RTU, SCADA, and PAC platforms when designing industrial infrastructure. Understanding the functional boundaries of each technology ensures optimal system performance, high availability, and long-term cost efficiency.

Read more