PRODUCT SKU : 1769-OW8I

PRODUCT TYPE : Discrete Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1769-OW8I is an 8-channel AC/DC relay output module designed for CompactLogix and MicroLogix 1500 controllers. Each output is individually isolated, supporting a wide operating voltage range and providing reliable control for discrete devices such as solenoids, lamps, and actuators. The module combines compact design, flexible mounting, and low power dissipation, making it suitable for high-density I/O configurations in industrial control panels.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model Number: 1769-OW8I

  • Series: CompactLogix / Compact I/O

  • Product Type: Discrete Output Module

  • Number of Outputs: 8 individually isolated relay outputs

  • Output Type: AC/DC relay, normally open

  • Compatible Controllers: MicroLogix 1500, CompactLogix series

  • Operating Voltage Range: 5–265 VAC, 5–125 VDC

  • Signal Delay (ON): 10 milliseconds

  • Bus Current Draw: 125 mA @ 5.1 VDC, 100 mA @ 24 VDC

  • Wire Compatibility:

    • Solid: 22–14 AWG copper

    • Stranded: 22–16 AWG copper

  • Slot Width: 1

  • Power Supply Compatibility: 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4

  • Heat Dissipation: 2.83 W

  • Mounting: DIN rail or panel mount

  • Series Designation: A and B

  • Communication Cable Support: 8-point I/O connections

  • Weight: 0.23 kg (0.50 lb)

Application Scenarios

The 1769-OW8I module is commonly used for:

  • Switching AC/DC loads in CompactLogix control panels

  • Controlling solenoids, relays, and indicator lights in machinery

  • Compact systems requiring reliable high-voltage relay outputs

  • Automation setups where individual isolation of channels is essential

Comparison with Similar Modules

  • 1769-OW8: AC relay output module with similar 8-point design

  • 1769-OB8: Transistor output module for DC load switching

  • 1769-OW16: Larger 16-point relay output module for expanded systems

FAQ

Q: Can the 1769-OW8I control both AC and DC devices?
A: Yes, it supports AC loads up to 265 V and DC loads up to 125 V.

Q: How are the outputs isolated?
A: Each of the 8 channels is individually isolated to prevent interference between loads.

Q: Which CompactLogix power supplies are compatible with this module?
A: Compatible power supplies include 1769-PA2, 1769-PB2, 1769-PA4, and 1769-PB4.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more