PRODUCT SKU : 1734-IB4

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Allen-Bradley 1734-IB4 is a compact POINT I/O digital input module featuring four sinking input channels designed for 24 V DC control systems. It provides reliable signal acquisition for distributed I/O architectures, offering flexible mounting and simplified wiring through the POINT I/O backplane. Its open-style housing and DIN-rail design make it ideal for use in tight control enclosures or modular installations.

Key Features

  • Four sinking digital input channels for 24 V DC logic signals

  • Compact POINT I/O format, optimized for distributed and modular automation

  • Open-style housing with quick DIN-rail installation

  • Compatible with 1734-TBS and 1734-TB terminal bases

  • Low power draw and high input integrity for efficient control performance

  • Designed for integration with CompactLogix and ControlLogix platforms

Technical Specifications

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Model Number: 1734-IB4

  • Product Type: POINT I/O Sink Input Module

  • Number of Inputs: 4 sinking inputs

  • Input Type: Digital, 24 V DC

  • Input Voltage Range: 10 – 28.8 V DC

  • Input Current (Nominal): 3.0 mA @ 24 V DC

  • Input Delay (Typical): 1.0 ms ON / 1.0 ms OFF

  • Isolation Voltage: 50 V continuous, reinforced insulation (field ↔ system)

  • POINTBus Current Draw: 75 mA @ 5 V DC

  • Mounting: DIN-rail via 1734-TBS or 1734-TB base

  • Housing Style: Open

  • Power Dissipation: 0.6 W (max.)

  • Dimensions (H × W × D): 7.55 × 1.2 × 5.6 cm

  • Weight: Approx. 0.02 kg (0.04 lb)

Performance and Reliability
The module is engineered for stable performance under continuous industrial operation. Each input channel provides fast response times and electrical isolation, ensuring dependable digital signal handling in PLC-based automation networks.

Applications

  • Packaging and material-handling equipment

  • Machine tools and assembly lines

  • Building and facility automation

  • Process control and distributed I/O systems

FAQ

Q1: What type of input signal does the 1734-IB4 accept?
A1: It supports 24 V DC sinking digital inputs for on/off signal detection.

Q2: Can this module be installed while the system is running?
A2: Yes, the POINT I/O architecture allows hot-swapping for minimal downtime.

Q3: Which base assemblies are compatible with the 1734-IB4?
A3: It mounts on 1734-TB or 1734-TBS terminal bases.

Q4: What is the recommended operating voltage range?
A4: The module operates between 10 V DC and 28.8 V DC, nominal 24 V DC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more