PRODUCT SKU : 1734-AENT

PRODUCT TYPE : Communication Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1734-AENT is a Point I/O EtherNet/IP adapter module that enables distributed I/O systems to seamlessly integrate into Ethernet networks.
It provides high-speed data exchange and flexible I/O expansion, making it suitable for industrial applications requiring modular control and efficient communication between controllers and field devices.
This adapter allows multiple I/O modules to connect through a single Ethernet node, reducing wiring complexity and installation time.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1734-AENT

  • Product Type: Point I/O EtherNet/IP Communication Adapter

  • Series: Bulletin 1734 Point I/O

Electrical Characteristics

  • Input Voltage Range: 10…28.8V DC

  • Nominal Input Voltage: 24V DC

  • Power Consumption: 4.5 W max @ 28.8V DC

  • Power Dissipation: 15.5 W max @ 28.8V DC

  • PointBus Output Current: 1 A max @ 5V DC (±5%)

  • Input Protection: Reverse polarity protected

  • Thermal Dissipation: 9.5 BTU/hr max @ 28.8V DC

Communication & Network

  • Communication Protocol: EtherNet/IP

  • Network Speed: 10/100 Mbps, half/full duplex auto-negotiation

  • Supported Topologies: Star, linear, and device-level ring (DLR)

  • IP Addressing: DHCP, BOOTP, or static configuration

  • Maximum Number of I/O Modules: 63 per adapter

  • LED Indicators: Network status, module status, and PointBus status

Mechanical & Environmental Specifications

  • Dimensions (H × W × D): 133.5 × 54.9 × 76.2 mm

  • Weight: 0.3 kg (0.66 lb)

  • Mounting Type: DIN rail (IEC/EN 60715)

  • Enclosure Type: Open-style (IP20)

  • Isolation Voltage: 1800V DC for 60 seconds

  • Operating Temperature: 0°C to +55°C (32°F to 131°F)

  • Storage Temperature: −40°C to +85°C (−40°F to 185°F)

  • Relative Humidity: 5–95% non-condensing

  • Vibration: 5 g @ 10–500 Hz

  • Shock Resistance: 30 g operating, 50 g non-operating

Application Notes

The 1734-AENT module is used in distributed I/O systems for process control, packaging machinery, and automotive manufacturing.
It supports real-time communication with Logix controllers over EtherNet/IP networks, ensuring deterministic performance and reliable operation.
Its modular design allows engineers to add or remove I/O points without disrupting network communication.

FAQ

Q: What is the maximum number of Point I/O modules supported by the 1734-AENT?
A: Up to 63 Point I/O modules can be connected per adapter.

Q: Does the adapter support redundant Ethernet connections?
A: Yes, it supports Device-Level Ring (DLR) topology for network redundancy.

Q: How is the module powered?
A: The adapter operates on a 24V DC supply, with reverse polarity protection included.

Q: Is configuration possible via USB?
A: No, configuration is handled over Ethernet using Studio 5000 or BOOTP/DHCP tools.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Examples of SCADA and PLC Configuration Systems in Industrial Automation

Examples of SCADA and PLC Configuration Systems in Industrial Automation

Learn how SCADA and PLC configurations are structured across small, medium, and large-scale industrial facilities. Explore system design strategies, redundancy requirements, and best practices for reliable industrial automation.

Read more
Applications of SCADA in Industrial Automation

Applications of SCADA in Industrial Automation

Discover how SCADA systems revolutionize industrial automation by enabling remote control, data analysis, and real-time process optimization across industries such as power, water, transportation, and manufacturing.

Read more
Main Components of a SCADA System in Industrial Automation

Main Components of a SCADA System in Industrial Automation

Discover the key components of a SCADA system and how sensors, RTUs, master units, and communication networks integrate to monitor and control industrial processes in real time.

Read more