Product Overview

The Yokogawa S9129FA serves as the dedicated backup power solution for the VFD10D module within Yokogawa Distributed Control Systems (DCS). This Nickel-Metal Hydride (NI-MH) battery pack provides critical energy to maintain volatile memory and configuration data during main power loss. By preventing data erasure in the VFD10D unit, the S9129FA ensures the control system resumes operation instantly without requiring time-consuming manual reloads or system re-initialization.

Technical Specifications

The S9129FA utilizes high-stability cell chemistry to provide long-term voltage support:

Parameter Specification
Manufacturer Yokogawa
Model Number S9129FA
Product Type NI-MH Battery Pack
Nominal Voltage 2.4 V
Compatible Hardware VFD10D Lithium Battery Replacement/Backup
Cell Chemistry Nickel-Metal Hydride (NI-MH)
Condition 100% Brand New and Original

Engineering Advantages

  • Stable Voltage Discharge: The NI-MH chemistry within the S9129FA delivers a highly consistent 2.4 V output. This stability prevents the voltage drops that lead to RAM corruption, ensuring the VFD10D module retains its logic and parameters throughout the duration of a power outage.

  • Extended Service Life: This battery pack withstands the continuous trickle-charging cycles common in industrial control nests. The internal cells resist the "memory effect," maintaining their full charge capacity over years of standby operation in the DCS cabinet.

  • Tool-Free Installation: The S9129FA features a specialized keyed connector designed specifically for Yokogawa hardware. This design eliminates the risk of reverse polarity during installation and allows maintenance teams to perform battery swaps in cramped marshalling cabinets quickly and safely.

  • Environmental Tolerance: The battery housing utilizes industrial-grade materials that resist the high ambient temperatures often found in non-ventilated control rooms. This thermal resilience prevents chemical leakage and ensures the battery functions reliably at the end of its service life.

FAQs

  • Is the Yokogawa S9129FA battery pack supplied as new?

    Yes. We supply the S9129FA strictly as 100% Brand New and Original equipment. Every battery pack arrives in its factory-sealed Yokogawa packaging, ensuring you receive the full chemical service life rated by the manufacturer.

  • Can I use the S9129FA to replace old lithium-style batteries?

    The S9129FA specifically serves as the NI-MH equivalent for systems utilizing the VFD10D architecture. While it replaces the function of previous backup solutions, always verify that your specific module revision supports the 2.4 V NI-MH charging circuit before installation.

  • How often should I replace this battery pack?

    Yokogawa typically recommends a replacement interval based on the ambient temperature of your control room. Under standard conditions, we suggest replacing the S9129FA every 2.4 to 3 years to ensure the cells remain capable of holding a full charge during an emergency.

  • Does this battery pack require a full charge before installation?

    The system's internal charging circuit will manage the battery once installed. However, we recommend checking the "Battery Low" alarm on the DCS console after 24 hours of operation to confirm the S9129FA has reached its nominal operating voltage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more