Skip to content

What are you looking for?


You may also like

Yokogawa S9129FA VFD10D NI-MH Battery PackYokogawa S9129FA VFD10D NI-MH Battery PackYokogawa S9129FA VFD10D NI-MH Battery Pack
Yokogawa S9129FA VFD10D NI-MH Battery Pack
Yokogawa S9129FA VFD10D NI-MH Battery Pack
Yokogawa S9129FA VFD10D NI-MH Battery Pack

Yokogawa S9129FA VFD10D NI-MH Battery Pack


Only 10 left - Selling fast

PRODUCT SKU : S9129FA

PRODUCT TYPE : Battery Pack

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa S9129FA serves as the dedicated backup power solution for the VFD10D module within Yokogawa Distributed Control Systems (DCS). This Nickel-Metal Hydride (NI-MH) battery pack provides critical energy to maintain volatile memory and configuration data during main power loss. By preventing data erasure in the VFD10D unit, the S9129FA ensures the control system resumes operation instantly without requiring time-consuming manual reloads or system re-initialization.

Technical Specifications

The S9129FA utilizes high-stability cell chemistry to provide long-term voltage support:

Parameter Specification
Manufacturer Yokogawa
Model Number S9129FA
Product Type NI-MH Battery Pack
Nominal Voltage 2.4 V
Compatible Hardware VFD10D Lithium Battery Replacement/Backup
Cell Chemistry Nickel-Metal Hydride (NI-MH)
Condition 100% Brand New and Original

Engineering Advantages

  • Stable Voltage Discharge: The NI-MH chemistry within the S9129FA delivers a highly consistent 2.4 V output. This stability prevents the voltage drops that lead to RAM corruption, ensuring the VFD10D module retains its logic and parameters throughout the duration of a power outage.

  • Extended Service Life: This battery pack withstands the continuous trickle-charging cycles common in industrial control nests. The internal cells resist the "memory effect," maintaining their full charge capacity over years of standby operation in the DCS cabinet.

  • Tool-Free Installation: The S9129FA features a specialized keyed connector designed specifically for Yokogawa hardware. This design eliminates the risk of reverse polarity during installation and allows maintenance teams to perform battery swaps in cramped marshalling cabinets quickly and safely.

  • Environmental Tolerance: The battery housing utilizes industrial-grade materials that resist the high ambient temperatures often found in non-ventilated control rooms. This thermal resilience prevents chemical leakage and ensures the battery functions reliably at the end of its service life.

FAQs

  • Is the Yokogawa S9129FA battery pack supplied as new?

    Yes. We supply the S9129FA strictly as 100% Brand New and Original equipment. Every battery pack arrives in its factory-sealed Yokogawa packaging, ensuring you receive the full chemical service life rated by the manufacturer.

  • Can I use the S9129FA to replace old lithium-style batteries?

    The S9129FA specifically serves as the NI-MH equivalent for systems utilizing the VFD10D architecture. While it replaces the function of previous backup solutions, always verify that your specific module revision supports the 2.4 V NI-MH charging circuit before installation.

  • How often should I replace this battery pack?

    Yokogawa typically recommends a replacement interval based on the ambient temperature of your control room. Under standard conditions, we suggest replacing the S9129FA every 2.4 to 3 years to ensure the cells remain capable of holding a full charge during an emergency.

  • Does this battery pack require a full charge before installation?

    The system's internal charging circuit will manage the battery once installed. However, we recommend checking the "Battery Low" alarm on the DCS console after 24 hours of operation to confirm the S9129FA has reached its nominal operating voltage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more