Only 10 left - Selling fast

PRODUCT SKU : NFTR8S-10

PRODUCT TYPE : Terminal Block Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa NFTR8S-10 serves as a critical interface component within the CENTUM VP integrated control system. This S2 terminal block module facilitates secure, high-density signal wiring between field instrumentation and the system's I/O modules. Precision-engineered in Japan, this module ensures seamless data integrity for demanding industrial automation environments. We supply this unit as 100% Brand New and in original manufacturer packaging to guarantee peak performance.

Part Number Breakdown

Yokogawa utilizes a specific alphanumeric coding system to define the hardware configuration of their interface modules:

Code Segment Definition Description
NFTR Product Class Terminal Block Module for S2 series
8 Connection Points Standardized port density
S Module Style S2 Series specific design
-10 Revision/Option Standard configuration for universal compatibility

Technical Specifications

The NFTR8S-10 features a compact footprint designed for high-density DIN rail or cabinet mounting.

  • Manufacturer: Yokogawa Electric Corporation

  • Origin: Japan

  • Weight: 0.1 kg (Ultra-lightweight design)

  • Dimensions: 2.2 cm x 12.4 cm x 12.6 cm

  • Compatibility: CENTUM VP S2 I/O Systems

  • Condition: 100% Brand New and Original

Engineering Advantages

The NFTR8S-10 solves several critical field-wiring challenges:

  • Optimized Space Utilization: The slim 2.2 cm width allows engineers to maximize cabinet density, effectively reducing the overall footprint of the control room hardware.

  • Enhanced Signal Integrity: High-quality contact points eliminate intermittent signal loss, a common failure point in aged or inferior third-party terminal blocks.

  • Simplified Maintenance: The modular design permits rapid replacement without disturbing adjacent wiring. This "plug-and-play" capability minimizes downtime during emergency repairs.

  • Vibration Resistance: The internal clamping mechanism maintains a constant pressure on wire leads, preventing loose connections in high-vibration industrial environments.

FAQs

Is the NFTR8S-10 compatible with older CENTUM CS 3000 systems?

Yes. While Yokogawa primarily designs the NFTR8S-10 for the CENTUM VP S2 series, it maintains backward compatibility with specific CS 3000 R3 I/O configurations. Always verify your specific I/O module suffix before installation.

What precautions should technicians take during installation?

Ensure the input/output signals match the module's rated voltage and current. We recommend using ferrule terminals for all field wiring to prevent fraying and to ensure a gas-tight connection within the terminal block.

Does this module require external power?

No. The NFTR8S-10 operates as a passive termination interface. It draws no power and functions strictly to route signals from field devices to the upstream I/O module.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more