Skip to content

What are you looking for?


You may also like

Yokogawa CP703 CENTUM CS Enhanced CPU CardYokogawa CP703 CENTUM CS Enhanced CPU CardYokogawa CP703 CENTUM CS Enhanced CPU Card
Yokogawa CP703 CENTUM CS Enhanced CPU Card
Yokogawa CP703 CENTUM CS Enhanced CPU Card
Yokogawa CP703 CENTUM CS Enhanced CPU Card

Yokogawa CP703 CENTUM CS Enhanced CPU Card


Only 10 left - Selling fast

PRODUCT SKU : CP703

PRODUCT TYPE : CPU Card

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa CP703 represents the enhanced processing core for the Field Control Stations (FCS) within the CENTUM CS distributed control system architecture. Designed specifically for large-scale plant operations, this CPU card manages complex control computations, high-density I/O signal processing, and integrated logic operations. We provide this module as 100% Brand New and Original, ensuring your system maintains peak execution speed and database stability for mission-critical automation.

Technical Specifications

The CP703 provides double the memory capacity of the standard CP701 model to accommodate advanced system software requirements.

Feature Specification Details
System Architecture CENTUM CS Compatible
Memory Capacity 16 MB (Enhanced System Model)
Network Interface VLnet Connectivity
Signal Compatibility Analog, Digital, and RS-232C Communication
Functionality Input Processing, Control Computation, Logic Operations
Station Interoperability Seamless HIS, Gateway, and Database Sync
Condition 100% Brand New Original

Engineering Advantages

  • High-Capacity Computation: The 16 MB memory on the CP703 supports sophisticated control algorithms and larger databases than the standard 8 MB CP701. This extra overhead prevents processor bottlenecks during intensive logic operations and high-frequency control loops in large-scale plants.

  • Unified System Architecture: Because the CP703 shares the same core architecture as the broader CENTUM CS family, it ensures seamless horizontal and vertical compatibility. This allows for stable expansion across different plant scales without requiring fundamental changes to the control philosophy.

  • Reliable VLnet Integration: The card utilizes VLnet connectivity to bridge the gap between Field Control Stations and Human Interface Stations (HIS). This high-speed link ensures that real-time data from the field reaches the operator's screen without latency, facilitating immediate response to process variables.

  • Versatile I/O Management: The CP703 manages a diverse array of signals, including specialized RS-232C communication lines. This capability allows for direct integration with third-party analytical instruments and serial devices, centralizing data management within a single FCS environment.

FAQs

What is the primary difference between the CP701 and CP703 CPU cards?

The CP703 serves as the "Enhanced" model, featuring 16 MB of memory, whereas the CP701 is the "Basic" model with 8 MB. Choose the CP703 if your system software requires more memory for complex logic or extensive database management.

Does the CP703 require specific software versions?

Yes. Model selection depends entirely on your system software requirements. Enhanced software packages designed for large-scale or memory-intensive control usually mandate the use of the CP703.

Can I upgrade an existing CP701 station to a CP703?

In most cases, yes, because they share the same architecture. Upgrading to a 100% Brand New CP703 provides an immediate memory boost, allowing for more complex control strategies without replacing the entire FCS chassis.

Is this unit refurbished or a pull-out from a decommissioned plant?

No. We sell only 100% Brand New Yokogawa hardware. Each CP703 ships in original factory packaging with a unique serial number to guarantee authenticity and ensure a full operational lifecycle within your system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more