Skip to content

What are you looking for?


You may also like

Yokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input ModuleYokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input ModuleYokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input Module
Yokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input Module
Yokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input Module
Yokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input Module

Yokogawa AAR145-S50 CENTUM VP/FIO RTD and POT Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAR145-S50

PRODUCT TYPE : RTD Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AAR145-S50 functions as a high-density Analog Input Module specifically designed for the CENTUM VP and CS 3000 FIO (Field network I/O) architectures. This module provides 16 isolated channels to interface with RTD (Resistance Temperature Detector) and POT (Potentiometer) sensors. It converts variable resistance signals from the field into precise digital data for the Distributed Control System (DCS). We supply this module as 100% brand new, original factory stock to ensure measurement accuracy and system stability for your non-hazardous area process control.

Part Number Breakdown: AAR145-S50

  • AAR145: RTD/POT Input Module (16-channel, Isolated).

  • -S: Standard type for general industrial applications.

  • 5: With no explosion protection (Optimized for standard control room environments).

  • 0: Basic type without specialized conformal coating.

Technical Specifications

  • Manufacturer: Yokogawa

  • Input Type: RTD (Resistance Temperature Detector) / POT (Potentiometer)

  • Number of Channels: 16 (Fully Isolated)

  • Data Update Period: 1 second

  • Excitation Current: 1 mA (for RTD measurement)

  • Isolation: Channel-to-channel and Channel-to-system isolation

  • Mounting: Plug-in installation on FIO baseplate

  • Signal Connection: Dedicated KS8 / AKB335 cable interface

  • Condition: 100% Brand New Original

Engineering Advantages

The AAR145-S50 optimizes thermal and position monitoring through advanced electrical shielding and high-density design:

  • Comprehensive Signal Isolation: This module employs complete electrical isolation across all 16 channels. This prevents ground loops and ensures that a field-side electrical surge or sensor failure on one channel does not interfere with the accuracy of the remaining 15 inputs.

  • Dual-Function Versatility: The AAR145-S50 handles both temperature (RTD) and position/resistance (POT) signals. This flexibility allows engineers to standardize on a single module type for diverse sensing needs, reducing the total spare parts inventory required for the facility.

  • High-Resolution Resistance Tracking: The module utilizes a stable 1 mA excitation current to maintain high-precision readings over long cable runs. It compensates for lead-wire resistance, ensuring that the DCS receives the actual process value rather than a signal skewed by wiring distance.

  • Efficient Cabinet Footprint: The high-density 16-channel architecture maximizes I/O capacity within the FIO nest. This allows for more monitoring points in a smaller physical space, significantly lowering the total cost of cabinet infrastructure and installation.

FAQs

  • What is the primary difference between the S00 and S50 versions?

    The S50 suffix indicates that the module provides no explosion protection. Use this version specifically in non-hazardous areas or standard industrial control rooms where explosion-proof certification is not a requirement.

  • Does this module support both 3-wire and 4-wire RTD configurations?

    Yes. The AAR145-S50 supports standard RTD wiring configurations to provide lead-wire compensation, ensuring accurate temperature measurements regardless of the distance between the sensor and the I/O cabinet.

  • How do I connect field wiring to the AAR145-S50?

    This module requires a dedicated Yokogawa cable (typically the KS8 or AKB335 series) to connect the module to the terminal board. This ensures secure, noise-free signal transmission from the field terminals to the DCS backplane.

  • Is this a genuine Yokogawa component?

    We guarantee that every AAR145-S50 we ship is 100% brand new and original. Each unit arrives in its original factory packaging and includes our comprehensive 1-year warranty.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more