Skip to content

What are you looking for?


You may also like

VF701 | Yokogawa CENTUM VP Vnet/IP Interface CardVF701 | Yokogawa CENTUM VP Vnet/IP Interface CardVF701 | Yokogawa CENTUM VP Vnet/IP Interface Card
VF701 | Yokogawa CENTUM VP Vnet/IP Interface Card
VF701 | Yokogawa CENTUM VP Vnet/IP Interface Card
VF701 | Yokogawa CENTUM VP Vnet/IP Interface Card

VF701 | Yokogawa CENTUM VP Vnet/IP Interface Card


Only 10 left - Selling fast

PRODUCT SKU : VF701

PRODUCT TYPE : Interface Card

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa VF701 acts as the high-performance communication gateway for the CENTUM VP Distributed Control System (DCS). This Vnet/IP interface card enables real-time, deterministic data exchange between the Human Interface Station (HIS) or Engineering Station (ENG) and the control network. By leveraging standard Ethernet physical layers with Yokogawa's specialized priority control, the VF701 ensures stable process monitoring and rapid command execution across the entire plant architecture.

Technical Specifications

The VF701 requires specific host hardware parameters to maintain peak communication integrity within a Vnet/IP environment:

Feature Minimum System Requirement / Specification
Manufacturer Yokogawa
Model VF701
Product Type Vnet/IP Interface Card
Host CPU Core2 Duo $\ge$ 2.13 GHz / Xeon Dual Core $\ge$ 2.0 GHz
System Memory 6 GB RAM
Storage Space 20 GB Free Disk Space
Display Support SXGA (1280x1024), True Color (16.77M colors)
Expansion Slot 1 Dedicated Slot for Control Network Interface
Optical Support DVD-ROM (for driver installation)
Shipping Weight 2 kg
Condition 100% Brand New and Original

Engineering Advantages

  • Deterministic Vnet/IP Throughput: The VF701 manages high-speed data packets without the "best-effort" latencies found in standard IT networking. It prioritizes control signals over general traffic, ensuring the operator console receives critical process alarms and variables with millisecond-level synchronization.

  • Large-Capacity Data Handling: Optimized for high-tag-count environments, the VF701 supports the 6GB memory architecture of modern CENTUM VP stations. This capacity allows the card to process massive amounts of historical data and real-time trends simultaneously without degrading bus performance.

  • Hardware-Level Reliability: Yokogawa engineers this card for continuous 24/7 operation. The robust design handles the thermal demands of industrial workstations, significantly reducing the risk of communication loss during critical process transitions.

  • Streamlined Network Integration: The VF701 occupies a single expansion slot, simplifying the hardware configuration of the host PC. Its compatibility with standard SXGA and True Color displays ensures that technicians view complex process graphics with high clarity and color accuracy for better situational awareness.

FAQs

  • Is this Yokogawa VF701 unit brand new or refurbished?

    We supply the VF701 strictly as 100% Brand New and Original equipment. Every card ships in its original Yokogawa factory packaging, complete with all factory seals and anti-static protection to ensure zero-hour reliability.

  • Does the VF701 support dual-redundant network configurations?

    Yes. In a typical CENTUM VP architecture, engineers often install two VF701 cards in a redundant configuration. This setup allows the system to switch communication paths instantaneously if one card or network cable fails, ensuring uninterrupted plant control.

  • What are the CPU requirements for installing the VF701?

    To ensure the card functions correctly, your workstation must utilize at least a Core2 Duo (2.13 GHz) or a Xeon Dual Core (2.0 GHz) processor. Insufficient CPU power can cause data processing bottlenecks and delay screen updates on the HIS.

  • Which cable type should I use with the VF701?

    The VF701 utilizes standard high-quality CAT5e or CAT6 Ethernet cabling for Vnet/IP communication. However, always follow Yokogawa’s specific grounding and shielding guidelines to prevent electromagnetic interference (EMI) from disrupting the control bus.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more