The Yokogawa NFTC5S-00, also cataloged as the NFTC5S Terminal Board, operates as a dedicated hardware component for field wiring termination and signal routing within Yokogawa CENTUM VP and CENTUM CS 3000 Field I/O (FIO) subsystems.

Suffix Breakdown & Model Matrix

  • NFTC5S: Base model designating Field I/O terminal board assembly for CENTUM control systems.
  • -00: Standard basic hardware specification option.

Hardware Specifications

Parameter Specification
Model NFTC5S-00
Brand Yokogawa
Origin Japan
Subsystem FIO (Field I/O)
Compatible Systems CENTUM VP / CENTUM CS 3000
Signal Types Dependent on paired I/O module (Digital or Analog)
Wiring Method Screw-type terminals
Isolation Terminal-to-system isolation
Weight Approx. 0.25 kg
Dimensions Standard Yokogawa FIO Terminal Board Assembly
Operating Temp -20 to 60 deg C
Power Consumption Passive Component (Zero Power Dissipation)

Yokogawa Signal Distribution & Channel Isolation Interface

The NFTC5S-00 routes discrete and analog field conductors through a dedicated backplane connector directly into paired I/O module slots. Integrated terminal isolation limits high-frequency field noise coupling into 4-20 mA HART loop protocol pairs and FOUNDATION Fieldbus signal channels. Dedicated shield grounding terminals maintain signal integrity between field devices and internal A/D converter buses across the control system platform.

Frequently Asked Questions

Q: Does the NFTC5S-00 terminal board require a separate DC power supply connection?

A: No, the NFTC5S-00 operates as a passive wiring interface block that passes electrical signals directly to the baseplate and paired I/O module without active power consumption.

Q: Can the NFTC5S-00 be replaced while field wiring remains intact?

A: Yes, the assembly releases directly from the Yokogawa baseplate and paired I/O module connection interface, allowing module maintenance without disturbing individual field screw terminals.

Field Installation Guidelines

Mount the NFTC5S-00 terminal board securely onto the designated Yokogawa I/O baseplate position until the backplane connector fully seats. Strip field conductor ends to specified gauge lengths and clamp each wire firmly into the screw terminals. Connect all instrument cable shields directly to the designated shield grounding terminal on the board, ensuring continuous bonding to the main cabinet single-point earth ground bar. Maintain physical separation between low-voltage signal wiring and AC power cables inside the panel wire ducts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more