Skip to content

What are you looking for?


You may also like

ATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital OutputATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital OutputATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital Output
ATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital Output
ATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital Output
ATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital Output

ATD5S-00 | Yokogawa Pressure Clamp Terminal Block for Digital Output


Only 10 left - Selling fast

PRODUCT SKU : ATD5S-00

PRODUCT TYPE : Terminal Block

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ATD5S-00 functions as a high-density, 32-point pressure clamp terminal block specifically engineered for digital output signal distribution in industrial automation environments. It facilitates secure, vibration-proof connections between the control system and field actuators. We supply this unit as 100% Brand New and Original, ensuring your DCS (Distributed Control System) maintains peak signal integrity and meets stringent regulatory standards.

Part Number Breakdown: ATD5S-00

Yokogawa utilizes the following suffix logic to define the hardware capabilities of the ATD5S series:

Code Specification Technical Detail
ATD5S Model Pressure Clamp Terminal Block for Digital Output (32-channel)
-0 Suffix Standard type without surge absorber
0 Suffix Fixed style code (Always 0)

Technical Specifications

The ATD5S-00 combines a compact form factor with robust environmental hardening:

  • Channel Capacity: 32-channel digital output

  • Connection Method: Pressure clamp terminal (screwless)

  • Environmental Standard: ISA Standard G3 compliant (Conformal coating)

  • Surge Protection: None (Configuration -0)

  • Mounting Compatibility: Standard 19-inch rack / DIN rail options

  • Weight: Approximately 0.20 kg

  • Application: Industrial automation and process control systems

Engineering Advantages

The ATD5S-00 optimizes field wiring and protects electronic hardware in demanding process plants:

  • Corrosion Resistance in Harsh Zones: This terminal block complies with ISA Standard G3, protecting copper traces and contact points from atmospheric corrosion caused by $H_2S$, $SO_2$, and high humidity. This feature ensures long-term electrical conductivity in wastewater treatment and chemical processing facilities.

  • Maintenance-Free Pressure Clamps: The spring-loaded pressure clamp mechanism maintains constant tension on the conductor. This design eliminates the need for periodic re-tightening—a common requirement with traditional screw terminals—and prevents signal loss caused by mechanical vibration from nearby rotating machinery.

  • High-Density Signal Management: By packing 32 digital output points into a slim 0.20 kg footprint, the ATD5S-00 significantly reduces the amount of rail space required in marshalling cabinets. This allows engineers to increase I/O density without expanding the physical enclosure size.

  • Simplified Commissioning: The tool-free wiring capability speeds up installation. Technicians insert stripped wires directly into the clamp, reducing labor costs and eliminating the risk of over-tightening or stripping screw threads during the setup phase.

FAQs

  • Does the ATD5S-00 require ferrules for stranded wire?

    While the pressure clamp secures bare stranded wire effectively, we recommend using insulated ferrules to prevent stray strands from causing short circuits in high-density 32-point configurations.

  • What happens if I encounter a voltage surge without a surge absorber?

    The ATD5S-00 configuration lacks an internal surge absorber. In environments prone to lightning or heavy inductive switching, you must install external surge protection devices to prevent transient voltages from reaching your I/O modules.

  • Can I use this terminal block for analog output signals?

    Yokogawa specifically designs the ATD5S series for digital output logic levels. Using it for sensitive analog signals may introduce impedance mismatches; therefore, we recommend using the dedicated analog series for precision loops.

  • Is this unit compatible with existing 19-inch racks?

    Yes, the ATD5S-00 adheres to standard Yokogawa mounting dimensions, fitting seamlessly into existing 19-inch rack-mounted DCS cabinets or DIN rail assemblies.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more