Product Overview

The Yokogawa ATC5S-00 functions as a high-integrity digital output interface specifically engineered for CENTUM VP and ProSafe-RS control architectures. This module executes precise switching commands for field-side devices, such as solenoid valves, actuators, and status indicators. By utilizing dedicated hardware isolation for each channel, the ATC5S-00 maintains superior signal purity even in electrically turbulent plant environments. We supply this module as 100% Brand New and original, ensuring factory-certified performance for your mission-critical DCS or SIS network.

Technical Specifications

The ATC5S-00 utilizes a ruggedized chassis designed for continuous operation within standard system racks.

  • Manufacturer: Yokogawa Electric Corporation

  • Model: ATC5S-00

  • Output Capacity: 8 Isolated Channels

  • Rated Output Voltage: 24 VDC

  • Max Output Current: 0.5 A per channel

  • Response Time: ≤ 5 ms

  • Isolation Voltage: 1500 VAC (Galvanic isolation)

  • Power Consumption: 2.5 W (Typical)

  • Operating Temperature: 0°C to 55°C

  • Humidity Range: 10–90% RH (Non-condensing)

  • Compatible Systems: CENTUM VP, ProSafe-RS

  • Weight: Approx. 0.8 kg

  • Condition: 100% Brand New and Original

Engineering Advantages

The ATC5S-00 addresses rigorous technical requirements through advanced circuit engineering:

  • Total Galvanic Isolation: The module features a 1500 VAC isolation barrier between the internal system logic and field wiring. This architecture prevents ground loops and blocks high-voltage transients from migrating to the central processor, effectively safeguarding the controller’s backplane.

  • High-Speed Logic Execution: With a response time of 5 ms or less, the module enables real-time synchronization between the controller's logic and field actuators. This speed proves essential for emergency shutdown (ESD) sequences and high-frequency process switching.

  • Optimized Thermal Dissipation: The module consumes only 2.5 W during typical operation. This low power draw reduces the heat load within the I/O nest, allowing for denser module packing without the risk of thermal derating or premature component failure.

  • Seamless SIS Integration: Unlike generic I/O, the ATC5S-00 interfaces directly with ProSafe-RS systems. It meets the stringent reliability standards required for safety instrumented systems, providing a stable platform for both basic control and safety-related functions.

FAQs

Which Yokogawa systems support the ATC5S-00?

The ATC5S-00 integrates natively with CENTUM VP (DCS) and ProSafe-RS (SIS) platforms. It fits standard Yokogawa system racks and communicates directly via the system bus without requiring specialized protocol converters.

What is the maximum current this module can drive?

Each of the 8 channels supports a maximum continuous load of 0.5 A. This capacity allows the module to drive most industrial-grade solenoids and interposing relays directly from the I/O rack.

How does the module handle high-humidity environments?

The ATC5S-00 features industrial coatings that allow operation in environments with up to 90% non-condensing relative humidity. This robust build prevents moisture ingress and terminal oxidation in typical process plant conditions.

Does the module require external fuses for each channel?

While the module includes internal protection, we recommend installing external fast-acting fuses or circuit breakers for field wiring to prevent permanent damage from short circuits or over-current events at the device level.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more