Skip to content

What are you looking for?


You may also like

DI2301 | Triconex 7400208C-020 Digital Input ModuleDI2301 | Triconex 7400208C-020 Digital Input ModuleDI2301 | Triconex 7400208C-020 Digital Input Module
DI2301 | Triconex 7400208C-020 Digital Input Module
DI2301 | Triconex 7400208C-020 Digital Input Module
DI2301 | Triconex 7400208C-020 Digital Input Module

DI2301 | Triconex 7400208C-020 Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : DI2301 7400208C-020

PRODUCT TYPE : Digital Input Modules

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal acquisition in safety-instrumented system platforms, the Triconex DI2301 7400208C-020 (DI2301 Digital Input Module) provides direct physical execution of field-to-logic state transition monitoring.

Hardware Specifications

Parameter Specification
Model DI2301 7400208C-020
Brand Triconex
Dimensions Standard 3U rack-mount module
Operating Temp -40 deg C to +70 deg C
Power Consumption Not specified
Channels 16 discrete digital inputs
Isolation 500 V

High-Reliability Safety Control and SIS Characteristics

The DI2301 module is designed for operation within Triconex triple modular redundancy (TMR) 2oo3 architecture, ensuring continuous signal integrity and fault tolerance for safety-critical inputs. The module features galvanically isolated input channels rated for 500 V, providing effective protection against ground loops and common-mode transients. Furthermore, the internal circuitry incorporates surge protection limits up to 1500 V to enhance resilience in electromagnetically noisy industrial environments. The module supports hot-swap capability, allowing for replacement without interrupting the system operation, provided the installation adheres to the defined safety logic requirements and TMR fault-tolerant protocols.

Frequently Asked Questions

Q: Can the DI2301 module be installed in any slot within the Tricon chassis?

A: The DI2301 must be matched with the corresponding baseplate (7400208C-020). While it is compatible with standard Tricon main or extension chassis, module placement must follow the system design documentation to ensure correct I/O mapping and TMR functionality.

Q: Is the DI2301 compatible with other module types in the same chassis?

A: Yes. The DI2301 can be integrated into the same cabinet and chassis alongside other Tricon modules, such as AI2351 or DO2401, to build a complete I/O subsystem.

Field Installation Guidelines

  1. Verify that the 7400208C-020 baseplate is securely mounted in the 3U rack and properly grounded before module insertion.
  2. Inspect the rear connector pins on the DI2301 module for any signs of physical obstruction or oxidation.
  3. Slide the module along the chassis guides until the locking latches engage, ensuring a firm electrical connection with the backplane.
  4. Verify field wiring terminations at the baseplate terminal blocks, ensuring that the 24 VDC loop configuration matches the input channel requirements.
  5. Utilize the system diagnostic software to confirm that the input states are being correctly acquired and processed by the CPU after installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more