Skip to content

What are you looking for?


You may also like

Emerson Epro PR6423/000-031-CN Eddy Current SensorEmerson Epro PR6423/000-031-CN Eddy Current SensorEmerson Epro PR6423/000-031-CN Eddy Current Sensor
Emerson Epro PR6423/000-031-CN Eddy Current Sensor
Emerson Epro PR6423/000-031-CN Eddy Current Sensor
Emerson Epro PR6423/000-031-CN Eddy Current Sensor

Emerson Epro PR6423/000-031-CN Eddy Current Sensor


Only 10 left - Selling fast

PRODUCT SKU : PR6423/000-031-CN

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for non-contact displacement measurement in machine monitoring systems, the Emerson Epro PR6423/000-031-CN (PR6423/000-031-CN) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model PR6423/000-031-CN
Brand Emerson Epro
Origin Germany
Weight Approx. 0.2 kg
Dimensions Standard probe housing geometry
Operating Temp -35 deg C to +200 deg C (Sensor)
Power Consumption Nominal excitation required
Measuring Range 8 mm
Air Gap 0.5 mm
Protection Class IP66

Eddy-current Probe Scaling

The PR6423/000-031-CN utilizes electromagnetic induction to provide a linear output proportional to the target distance. The Incremental Scale Factor (ISF) is calibrated to 8 V/mm (+/- 5%) at nominal operating temperatures to ensure compatibility with standard Epro monitoring modules. Precise gap voltage validation is required during initial commissioning to confirm the probe operates within its linear measurement region, typically targeting a mid-range -10 VDC baseline relative to the signal converter output. Deviations from this scaling indicate potential mechanical misalignment or target material inconsistency.

Frequently Asked Questions

Q: Does the PEEK sensor tip require specific handling precautions during installation?

A: Yes. While PEEK provides excellent thermal and mechanical stability, avoid using metal-jawed wrenches directly on the tip to prevent surface scarring, which can introduce signal noise.

Q: Is the IP66 rating applicable to the cable and connector assembly?

A: The IP66 rating applies to the sensor head. The connector assembly requires additional environmental protection if exposed to direct fluid ingress or high-pressure washdown in the field.

Field Installation Guidelines

  1. Mount the sensor in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise.
  2. Maintain a minimum shaft diameter of 25 mm for the target area to ensure linear flux density.
  3. Ensure the initial air gap is set to 0.5 mm using a non-metallic feeler gauge to prevent damage to the probe tip.
  4. Route the PTFE-insulated cable through grounded metallic conduit, keeping the lead away from high-current AC power lines to minimize induced electromagnetic interference.
  5. Tighten the lock nuts according to standard mechanical torque specifications for the stainless steel housing to prevent loosening under operational vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more