M60UA3HKHF8LH6NM8N6MU5AWXX GE Motor Protection Relay
M60UA3HKHF8LH6NM8N6MU5AWXX GE Motor Protection Relay
M60UA3HKHF8LH6NM8N6MU5AWXX GE Motor Protection Relay

M60UA3HKHF8LH6NM8N6MU5AWXX GE Motor Protection Relay


Only 10 left - Selling fast

PRODUCT SKU : M60UA3HKHF8LH6NM8N6MU5AWXX

PRODUCT TYPE : Motor Protection Relays

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE M60UA3HKHF8LH6NM8N6MU5AWXX, also cataloged as the M60 Motor Protection Relay, operates as a dedicated hardware component for motor protection, real-time metering, and automated fault logging within Multilin 8 Series and Universal Relay platforms. Configured for medium to large industrial motors, the unit processes primary current, voltage, and frequency signals to execute thermal overload, overcurrent, and phase differential trip functions while maintaining deterministic Ethernet communication.

Hardware Specifications

Parameter Specification
Model M60UA3HKHF8LH6NM8N6MU5AWXX
Brand GE
Origin USA
Weight 4.5 kg
Dimensions 35 cm x 25 cm x 13 cm
Operating Temp -25 to +60 deg C
Power Consumption Standard Internal Power Supply Draw
Product Type Motor Protection Relays
Storage Temp -40 to +70 deg C
Ethernet Ports Up to 3 ports (100 Mb fiber or copper)
Serial Interfaces RS485, RS232, RS422, G.703, C37.94
Protocols Supported IEC 61850, DNP 3.0, Modbus serial/TCP, IEEE 1588, IEC 60870-5-104/103, PRP, SNTP, HTTP, TFTP, EGD
Event Logging 1024-event recorder, 250 motor start logs, extended waveform capture

Deterministic Ethernet Communications and Firmware Integration

The GE M60UA3HKHF8LH6NM8N6MU5AWXX integrates multi-protocol Ethernet routing modules to maximize backplane bus communication velocity across automated station buses. High-speed process bus execution through IEC 61850 and PRP redundant networking prevents packet loss during transient network events. Direct board-level integration supports I/O density scaling and preserves firmware flash compatibility across protective relay controller racks.

Frequently Asked Questions

Q: How does the M60 relay capture motor start records?

A: The onboard non-volatile memory logs starting current, voltage drop, thermal capacity usage, and acceleration duration for the last 250 motor start events without overwriting master event files.

Q: What time synchronization methods are supported for precise waveform logging?

A: The unit supports IEEE 1588 Precision Time Protocol (PTP) and SNTP across its 100 Mb Ethernet ports to align event recorder timestamps across distributed protection architectures.

Q: Can the serial and Ethernet communication modules be used simultaneously?

A: Yes, serial interfaces (RS485/RS232/C37.94) and Ethernet ports operate concurrently, allowing simultaneous SCADA control via DNP 3.0 or Modbus and substation automation via IEC 61850.

Field Installation Guidelines

  1. Isolate all control power feeds and short-circuit CT secondary current transformer inputs prior to mounting the chassis.
  2. Insert the 35 cm x 25 cm x 13 cm housing into the panel cutout and tighten rear mounting brackets to maintain structural grounding.
  3. Terminate the safety earth ground stud directly to the station ground bus using a low-impedance copper conductor.
  4. Route high-voltage AC current/voltage input leads separately from fiber and copper Ethernet communication lines to minimize electromagnetic interference.
  5. Inspect all terminal block wiring and RJ45/LC fiber transceiver connections before restoring control auxiliary power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

Step-by-Step System Cabinet Health Check Guide for PLC and DCS Infrastructure

System cabinet health checks ensure long-term reliability in industrial automation. Preventative maintenance prevents hardware degradation, communication loss, and unplanned outages in control networks. This guide outlines the standard operating workflow for inspecting PLC and DCS cabinets to maintain peak performance.
Read more
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more