Skip to content

What are you looking for?


You may also like

Allen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal BlockAllen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal BlockAllen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal Block
Allen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal Block
Allen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal Block
Allen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal Block

Allen-Bradley 5069-RTB18-SCREW Compact 5000 I/O 18-Pin Removable Terminal Block


Only 10 left - Selling fast

PRODUCT SKU : 5069-RTB18-SCREW

PRODUCT TYPE : Terminal Block

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 5069-RTB18-SCREW serves as the primary physical interface for wiring field-side devices to the Allen-Bradley Compact 5000 I/O system. This 18-pin Removable Terminal Block (RTB) utilizes a classic screw-termination method to ensure high-integrity electrical contact for signal and power circuits. It enables rapid module replacement without disturbing the existing field wiring, significantly reducing downtime during maintenance. We provide this component as 100% Brand New original hardware, ensuring perfect mechanical fit and electrical conductivity for your Logix-based control panels.

Technical Specifications

The 5069-RTB18-SCREW meets precise mechanical standards for industrial connectivity:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Part Number 5069-RTB18-SCREW
Terminal Type Screw-Type Termination
Number of Pins 18 Pins
Compatibility Compact 5000 I/O Modules (5069 Series)
Housing Design Open-Style
Mounting Module-Mounted (Removable)
Shipping Weight 0.13 lbs (0.06 kg)

Engineering Advantages

  • High-Torque Screw Termination: The screw-type design provides superior clamping force for various wire gauges. This mechanical pressure ensures low-resistance connections and prevents wire pull-out in high-vibration environments.

  • Simplified Field Maintenance: The "Removable" nature of the RTB allows technicians to replace a failed I/O module in minutes. You simply unplug the wired RTB, swap the module, and re-seat the terminal block, eliminating the risk of cross-wiring errors.

  • Secure Locking Mechanism: The RTB locks firmly onto the front of the 5069 module. This secure fit maintains electrical continuity even when subject to the mechanical stresses typical of industrial machinery.

  • Clear Pin Identification: Precise numbering on the terminal housing facilitates accurate wire mapping. This clarity speeds up the initial installation process and simplifies future troubleshooting for maintenance crews.

  • Support for Diverse Wire Gauges: The screw terminals accommodate a wide range of solid and stranded wire sizes, offering the flexibility needed for various sensor and actuator types within a single control bank.

Installation Guidelines

  1. Torque Specifications: Apply the manufacturer-recommended torque to the terminal screws to ensure a gastight connection without stripping the threads.

  2. Wire Stripping: Strip the wire insulation to the correct length before insertion. Excess bare wire increases the risk of short circuits, while insufficient stripping leads to poor contact with the screw clamp.

  3. Seating the RTB: Align the RTB with the pins on the front of the 5069 module. Press firmly until the locking tabs click, indicating a complete and secure connection to the module backplane.

FAQs

Q: Does the 5069-RTB18-SCREW ship with the I/O module?

A: No. Allen-Bradley sells 5069 I/O modules and Removable Terminal Blocks separately. This allows engineers to choose between screw-type (5069-RTB18-SCREW) or spring-type (5069-RTB18-SPRING) terminations based on their specific application needs.

Q: Can I use this RTB with 1769 Compact I/O or 1734 POINT I/O modules?

A: No. The 5069-RTB18-SCREW only fits the Compact 5000 I/O (5069 series) platform. The physical dimensions and pin spacing differ from legacy 1769 and 1734 systems.

Q: What is the primary advantage of the screw type over the spring type?

A: Screw-type terminals provide a visible and high-torque mechanical connection. Many engineers prefer them for power distribution or in environments where they require the highest possible pull-out resistance for heavy-gauge field wiring.

Q: Is this terminal block compatible with all 5069 I/O modules?

A: It fits most 18-pin 5069 digital and analog modules. Always verify the pin count on your specific I/O module before purchase to ensure compatibility with the 18-pin configuration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more