Product Details

The Honeywell 51195096-200, also cataloged as the 51195096-200 Input/Output Circuit Board, operates as a dedicated hardware component for PLC Gateway interface communications within Honeywell TDC 3000 systems.

Hardware Specifications

Parameter Specification
Model 51195096-200
Brand Honeywell
Origin USA
Weight Approx. 0.68 kg (1.5 lb)
Dimensions Standard Honeywell TDC 3000 rack module size
Operating Temp 0 deg C to +60 deg C
Power Consumption Max. 12 W via chassis backplane
Series TDC 3000
Communication Protocols Modbus, non-redundant Allen-Bradley protocol
Interface Type Programmable Logic Controller Interface (PLCI)
Compliance CE Compliant
Mounting Type Chassis / Rack Mount

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The board enables continuous serial data conversion between the proprietary Honeywell TDC 3000 backplane architecture and external field PLCs running Modbus or Allen-Bradley protocols. High-grade channel-to-channel isolation safeguards the digital communication circuits against ground loops and common-mode voltage spikes, preventing noise propagation into analog 4-20 mA HART loop protocol signal paths operating within the same DCS enclosure.

Frequently Asked Questions

Q: Does the 51195096-200 board support redundant Allen-Bradley protocol links?

A: No, the board hardware is designed specifically for non-redundant Allen-Bradley communication paths alongside standard Modbus interface links.

Q: Can this module be hot-swapped while the TDC 3000 rack backplane is energized?

A: No, power to the rack backplane section must be isolated before removing or inserting the circuit board to prevent bus voltage transients and physical trace damage.

Q: How is physical protocol connectivity achieved on this card?

A: Communication cabling attaches via dedicated backplane pin arrays or faceplate cable headers configured for serial RS-232/RS-422/RS-485 level signaling to the external PLC network.

Field Installation Guidelines

  • Ensure backplane power supply rails are completely turned off prior to inserting the circuit card into the rack slot.
  • Ground the chassis frame in accordance with plant DCS grounding standards before connecting external serial communication cables.
  • Secure all interface cable retention screws to prevent signal loss from mechanical vibration in cabinet environments.
  • Maintain adequate vertical ventilation clearances within the TDC 3000 rack cabinet to prevent thermal stress on onboard semiconductors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more
Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Modern factory automation relies heavily on fiber optic cables for high-speed industrial data transmission. Fiber optic cables transmit light pulses instead of electrical signals, eliminating electromagnetic interference (EMI) risks completely. Each optical strand consists of a high-purity glass core surrounded by a protective cladding layer. The difference in refractive index between core and cladding enables total internal reflection. Protective resin buffers, Kevlar strength members, and rugged outer jackets safeguard delicate glass cores in harsh environments. Consequently, automation engineers prefer fiber backbones for reliable noise-free communication in industrial control systems.

Read more