Skip to content

What are you looking for?


You may also like

51304584-300 EPDGP I/O Board | Honeywell51304584-300 EPDGP I/O Board | Honeywell51304584-300 EPDGP I/O Board | Honeywell
51304584-300 EPDGP I/O Board | Honeywell
51304584-300 EPDGP I/O Board | Honeywell
51304584-300 EPDGP I/O Board | Honeywell

51304584-300 EPDGP I/O Board | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : 51304584-300

PRODUCT TYPE : Interface Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for peripheral interface signal routing in Honeywell Universal Station nodes, the Honeywell 51304584-300 (51304584 EPDGP I/O Board) provides direct physical/electrical execution for video, keyboard, cursor, and drive communications across Z-Console architectures.

Hardware Specifications

Parameter Specification
Model 51304584-300
Brand Honeywell
Origin USA
Operating Temp 0 deg C to +50 deg C
Power Consumption 15 W max at backplane supply rails
System Compatibility Honeywell Universal Station (EPDG and EPDG2)
Module Type Enhanced Process Display Generator Peripheral (EPDGP) I/O
Supported Interfaces Video, cursor control, keyboard, Zip/Bernoulli drive, parallel printer
Keyboard Compatibility 51401952-100, 51401952-200 operator keyboards
Hardware Configuration Jumper-selectable inverted sync and default background color

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The board isolates peripheral subsystem grounds from the main station bus to maintain signal stability across high-density operator consoles. By eliminating common-mode ground noise across video and serial peripheral links, the module prevents potential high-frequency cross-talk from interfering with adjacent cabinet signal buses carrying 4-20 mA HART loop protocol telemetry and field I/O processing paths.

Frequently Asked Questions

Q: What hardware revision level is required on the 51304584-300 for mass storage device support?

A: Rev G or higher is required to support Zip and Bernoulli drive interface communications.

Q: How is the default video display background configured on the board?

A: Onboard jumpers determine the default display state, allowing hardware selection between a grey or black background upon initialization.

Q: Is this module compatible with both EPDG and EPDG2 platform revisions?

A: Yes, the board integrates directly into Universal Station Z-Console architectures utilizing either EPDG or EPDG2 display generator assemblies.

Field Installation Guidelines

  • Power down the operator workstation chassis before seating the module into the card cage slot.
  • Observe static discharge safety protocols and wear a grounded wrist strap during installation.
  • Verify jumper configurations for video sync polarity and default background settings prior to applying backplane power.
  • Ensure terminal connections for peripheral keyboards and cursor devices are secured to avoid intermittent serial communication loss.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more
Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Industrial Fiber Optic Cables: Principles, Connectors, and Fusion Splicing Techniques

Modern factory automation relies heavily on fiber optic cables for high-speed industrial data transmission. Fiber optic cables transmit light pulses instead of electrical signals, eliminating electromagnetic interference (EMI) risks completely. Each optical strand consists of a high-purity glass core surrounded by a protective cladding layer. The difference in refractive index between core and cladding enables total internal reflection. Protective resin buffers, Kevlar strength members, and rugged outer jackets safeguard delicate glass cores in harsh environments. Consequently, automation engineers prefer fiber backbones for reliable noise-free communication in industrial control systems.

Read more