Product Details

Description

The HIMA H 4007 is a robust safety-related switching amplifier designed for critical industrial control and safety applications. It amplifies and conditions input signals for reliable transmission to HIMA safety controllers, ensuring uninterrupted operation even in demanding environments. The module’s compact design allows seamless integration into HIMA racks, supporting SIL-rated architectures. With high-frequency signal output up to 350 kHz, the H4007 enables precise and responsive control in complex automation processes, while intrinsic safety protection allows safe use in hazardous gas and dust environments.

Specifications

  • Manufacturer: HIMA

  • Model: H 4007

  • Product Type: Safety-Related Switching Amplifier

  • Input/Output: Amplifies and conditions signals for safe transmission

  • Output Frequency: Up to 350 kHz

  • Operating Voltage: 220 V AC

  • Intrinsic Safety: [Ex ib Gb] IIC (gas), [Ex ib Db] IIIC (dust)

  • SIL Rating: Suitable for SIL-rated safety applications

  • Mounting: DIN-rail or modular rack integration

  • Operating Temperature: –20°C to +60°C

  • Storage Temperature: –40°C to +85°C

  • Weight: 0.35 kg (approximate)

  • Dimensions: 90 mm x 45 mm x 75 mm (approximate)

Features

  • Explosion-Proof Design: Certified for hazardous gas and dust zones

  • High-Frequency Output: Supports signal output up to 350 kHz for rapid, precise control

  • Compact Modular Form Factor: Integrates easily into HIMA safety systems

  • SIL-Rated Capability: Ensures safe operation in critical safety instrumented systems

  • Intrinsic Safety Protection: Gas ([Ex ib Gb] IIC) and dust ([Ex ib Db] IIIC) protection

  • Reliable Industrial Operation: Designed for continuous, high-demand environments

  • Seamless Integration: Compatible with HIMA safety controllers for fault-tolerant operation

Typical Applications

  • Process monitoring and control in oil & gas and petrochemical plants

  • Explosion-proof signal handling in hazardous industrial zones

  • SIL-rated safety instrumented systems in power generation facilities

  • Automation systems requiring precise, high-frequency signal processing

FAQ

Q1: Can the H 4007 be used in dust-explosive zones?
A1: Yes, it is certified [Ex ib Db] IIIC for safe operation in dust-explosive environments.

Q2: What is the maximum output frequency of the H4007?
A2: The module supports signal output up to 350 kHz.

Q3: Is the H 4007 suitable for SIL-rated systems?
A3: Yes, it can be integrated into SIL-rated HIMA safety architectures.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
How to Train Your Maintenance Team for Industrial Automation Systems

How to Train Your Maintenance Team for Industrial Automation Systems

Proper training of maintenance teams is essential to prevent downtime and ensure smooth operations in industrial automation. With PLCs, DCS, SCADA, and IoT systems, technicians need advanced skills to manage complex control systems. This guide provides a structured approach to building a capable team.

Read more
Understanding Fail-Safe in Siemens PLCs for Industrial Automation

Understanding Fail-Safe in Siemens PLCs for Industrial Automation

In industrial automation, safety PLCs provide advanced protection beyond standard types. They safely shut down machinery during faults, reducing external hardware needs. Certified to SIL and IEC/ISO standards, they ensure functional safety in factory automation, protecting both personnel and critical equipment.

Read more
Understanding GE Fanuc Emerson Field Control for Industrial Automation

Understanding GE Fanuc Emerson Field Control for Industrial Automation

GE Fanuc Emerson’s Field Control I/O offered a compact, DIN-rail-mounted solution for industrial automation. Ideal for water treatment and process plants, its integrated design saved panel space and simplified wiring. Though reliable, this line is now obsolete, requiring a shift to modern, high-speed remote I/O.

Read more