Skip to content

What are you looking for?


You may also like

Woodward 8440-1831 easYgen-3200 Series Controller UnitWoodward 8440-1831 easYgen-3200 Series Controller UnitWoodward 8440-1831 easYgen-3200 Series Controller Unit
Woodward 8440-1831 easYgen-3200 Series Controller Unit
Woodward 8440-1831 easYgen-3200 Series Controller Unit
Woodward 8440-1831 easYgen-3200 Series Controller Unit

Woodward 8440-1831 easYgen-3200 Series Controller Unit


Only 10 left - Selling fast

PRODUCT SKU : 8440-1831

PRODUCT TYPE : Genset Controllers

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for genset management and synchronization, the Woodward 8440-1831 (8440-1831 Series Controller Unit) provides direct physical/electrical execution of generator monitoring and protection tasks.

Hardware Specifications

Parameter Specification
Model 8440-1831
Brand Woodward
Origin Not specified
Weight 2150 g
Dimensions 282 x 217 x 99 mm
Operating Temp Not specified
Power Consumption Max 14 W
Measuring Frequency 40 - 85 Hz
Input Resistance 2.0 M Ohm
Power Supply 8 - 40 VDC

V/Hz and Field-Oriented Vector Control

The 8440-1831 controller integrates FlexIn technology to manage various analog input signals, including resistive senders and 0/4-20 mA loops. This flexibility enables the unit to execute precise generator control loops, maintaining stable voltage and frequency regulation. The controller is designed to support field-oriented vector control logic, ensuring accurate phase matching during multiple-unit mains applications. Proper configuration of the MCB release and reply signals is required to maintain synchronization and harmonic distortion suppression across interconnected genset platforms.

Frequently Asked Questions

Q: Are the relay outputs on the 8440-1831 galvanically isolated?

A: Yes, the relay outputs are isolated to prevent electrical interference and protect the internal control circuitry from field-side voltage spikes.

Q: What are the requirements for the FlexIn analog inputs?

A: The three FlexIn analog inputs are software-configurable for VDO, resistive, or 0/4-20 mA sender types. Ensure that the sensor ground configuration (one-pole or two-pole) matches the controller's input settings to prevent signal offsets.

Field Installation Guidelines

  1. Handling: The housing is constructed of high-impact plastic; exercise caution during mounting to prevent mechanical stress or cracking of the enclosure.
  2. Mounting: Utilize the specified 282 x 217 x 99 mm footprint for panel integration. Ensure adequate clearance for terminal connections and heat dissipation.
  3. Wiring: For multiple-unit applications, ensure all connected controllers receive identical mains voltage and current feedback signals to prevent synchronization errors.
  4. Signal Shielding: Terminate cable shields at the designated cabinet ground point. Keep analog signal cabling separate from high-current AC output lines to avoid induced electromagnetic noise.
  5. Validation: Verify the DC power supply is within the 8-40 VDC range before commissioning. Confirm that the measuring frequency range (40-85 Hz) is compatible with the connected generator system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more