Skip to content

What are you looking for?


You may also like

Woodward 9905-968 Linknet Analog Input ModuleWoodward 9905-968 Linknet Analog Input ModuleWoodward 9905-968 Linknet Analog Input Module
Woodward 9905-968 Linknet Analog Input Module
Woodward 9905-968 Linknet Analog Input Module
Woodward 9905-968 Linknet Analog Input Module

Woodward 9905-968 Linknet Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 9905-968

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multi-channel sensor signal acquisition in gas turbine control platforms, the Woodward 9905-968 (9905-968 Channel Analog Input Module) provides direct physical/electrical execution. The hardware conditions and converts 4-20 mA analog inputs from field sensors into digital data streams for processing by central governing logic. Housed in a 16 cm x 16 cm x 12 cm enclosure weighing 1.82 kg, the unit routes conditioned real-time telemetry across dedicated Linknet communication channels.

Hardware Specifications

Parameter Specification
Model 9905-968
Brand Woodward
Origin United States
Weight 1.82 kg
Dimensions 16 cm x 16 cm x 12 cm
Operating Temp Standard Industrial Range (-20 deg C to +60 deg C)
Power Consumption Linknet Network / External 24 VDC Powered
Input Channel Count 6 Channels
Signal Input Type 4-20 mA Current Loop
Signal Processing Analog-to-Digital Conversion with Signal Conditioning
Architecture Linknet I/O Network Component

Actuator Loop Feedback Response

The Woodward 9905-968 Linknet Analog Input Module incorporates low-latency signal filtering and digitizing logic designed to preserve actuator loop feedback response. By executing high-speed sampling across all six 4-20 mA channels, the internal circuitry scales field pressure, temperature, and position sensor inputs without phase delay. Continuous signal conditioning suppresses high-frequency electrical noise, supplying noise-free telemetry to the main controller to prevent phase lag or hunting in hydraulic actuator control loops.

Frequently Asked Questions

Q: How is signal wire shield grounding handled for the 4-20 mA input loops?

A: All 4-20 mA input loop signal cables must use individual shielded twisted pairs. Connect signal cable drain shields to the enclosure single-point grounding bus bar at one end only to prevent ground loops from introducing current measurement offsets.

Q: Can channels be hot-swapped while the Linknet network is actively processing signals?

A: Live removal or insertion of the module while powered must follow strict safety procedures. De-energize field loops or disconnect the Linknet communication header to avoid transient bus disruptions and improper diagnostic trips within the primary control software.

Field Installation Guidelines

Mount the module inside a grounded metal control cabinet using the standard mounting hardware to ensure structural stability against mechanical vibration. Wire the 4-20 mA input channels using shielded twisted-pair conductors, maintaining physical separation between low-level analog signal lines and high-voltage AC lines or inductive output wiring. Ensure the cabinet earth ground strap is bonded directly to the main grounding point with a short, low-impedance conductor prior to powering the unit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more