5501-365 | Woodward | Analog Input/Output Module5501-365 | Woodward | Analog Input/Output Module5501-365 | Woodward | Analog Input/Output Module
5501-365 | Woodward | Analog Input/Output Module
5501-365 | Woodward | Analog Input/Output Module
5501-365 | Woodward | Analog Input/Output Module

5501-365 | Woodward | Analog Input/Output Module


Only 10 left - Selling fast

PRODUCT SKU : 5501-214

PRODUCT TYPE : Analog Input/Output Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for hydraulic signal regulation in governor control platforms, the Woodward 5501-365 (5501-365 Electro-hydraulic Converter) provides direct physical/electrical execution of electrical-to-hydraulic signal conversion.

Hardware Specifications

Parameter Specification
Model 5501-365
Brand Woodward
Dimensions 100 x 50 x 30 mm
Operating Temp -10 to 60 deg C
Power Consumption Not specified
Input Voltage 24 VDC
Output Voltage 0-10 VDC
Output Current 5 A
Communication RS485

Actuator Loop Feedback Response

The 5501-365 functions as an interface between electronic control signals and hydraulic actuation. To maintain a stable actuator loop feedback response, the converter utilizes high-precision internal circuitry to minimize deadband and hysteresis in the hydraulic output. The device accepts 24 VDC input power and processes electronic control commands into 0-10 VDC signals to modulate hydraulic servo valve positioning. The RS485 interface allows for remote monitoring of device status and calibration parameters, ensuring that the actuator response remains synchronized with the prime mover governing requirements under transient load conditions.

Frequently Asked Questions

Q: Does the module support real-time adjustments via the RS485 interface?

A: Yes, the RS485 communication interface allows for the monitoring and adjustment of internal calibration parameters. Ensure the master controller protocol matches the module's baud rate and address settings to maintain data communication integrity.

Q: What are the installation requirements to ensure thermal stability?

A: The device is rated for operation between -10 deg C and 60 deg C. Ensure the module is mounted in a location with adequate airflow, away from direct thermal radiation sources, to maintain the internal heat sink dissipation profiles within design limits.

Field Installation Guidelines

  1. Mounting: Secure the converter to a rigid, vibration-dampened surface using the designated mounting points on the 100 x 50 x 30 mm chassis.
  2. Electrical Wiring: Use shielded twisted-pair cabling for the RS485 communication link and high-current rated wire for the power and signal outputs to prevent voltage drops.
  3. Grounding: Connect the module's common reference to the control cabinet's earth bus to mitigate electromagnetic interference and ensure the accuracy of the 0-10 VDC output signal.
  4. Validation: Before applying hydraulic pressure, perform an electrical continuity check and verify the 24 VDC supply. Use a diagnostic tool to confirm the module responds correctly to control commands via the RS485 port.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more