Skip to content

What are you looking for?


You may also like

5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module
5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module
5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module
5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module

5464-551 | Woodward | Netcon 5000 Integrating Actuator Driver Module


Only 10 left - Selling fast

PRODUCT SKU : 5464-551

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Woodward 5464-551, also cataloged as the 5464-551 Integrating Actuator Driver Module, operates as a dedicated hardware component for turbine and engine control within Woodward Netcon 5000 platforms.

Hardware Specifications

Parameter Specification
Model 5464-551
Brand Woodward
Origin USA
Weight Approx. 1.2 kg
Dimensions Standard Netcon rack-mount chassis form factor
Operating Temp -20 deg C to +60 deg C
Power Consumption Dependent on actuator load profile
System Compatibility Netcon 5000
Signal Type Actuator Drive Output

Actuator Loop Feedback Response

The 5464-551 module manages high-speed actuator loop feedback, essential for maintaining stable turbine governor operation. It utilizes pulse-width modulation or current-based output scaling to ensure precise positioning of hydraulic or electric actuators. The module facilitates instantaneous response to control setpoint adjustments, minimizing overshoot in engine speed regulation. Thermal heat sink dissipation profiles are integrated into the module housing to maintain junction temperatures during continuous high-current actuator driving cycles.

Frequently Asked Questions

Q: Does the 5464-551 support hot-swap functionality within the Netcon 5000 rack?

A: No, module removal or insertion must be performed with rack power removed to prevent potential backplane electrical shorts and damage to the control logic circuitry.

Q: How should the actuator cable shield be terminated to prevent noise interference?

A: Shields must be terminated to a clean chassis ground at the module entry point. Avoid ground loops by ensuring the actuator side termination maintains consistent potential with the control cabinet ground reference.

Field Installation Guidelines

  1. Power down the Netcon 5000 rack prior to module insertion.
  2. Verify the physical slot alignment to ensure the backplane connector pins seat evenly.
  3. Secure the module using the front panel captive screws to ensure proper grounding and mechanical vibration resistance.
  4. Route high-current actuator wiring separately from sensitive analog signal cables to mitigate electromagnetic interference (EMI).
  5. Ensure all wiring terminals are tightened to the torque specified by the wiring harness manufacturer, typically 0.5 Nm to 0.8 Nm.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more