Skip to content

What are you looking for?


You may also like

GE Fanuc D25-0157-000003 Measurement and Control DeviceGE Fanuc D25-0157-000003 Measurement and Control DeviceGE Fanuc D25-0157-000003 Measurement and Control Device
GE Fanuc D25-0157-000003 Measurement and Control Device
GE Fanuc D25-0157-000003 Measurement and Control Device
GE Fanuc D25-0157-000003 Measurement and Control Device

GE Fanuc D25-0157-000003 Measurement and Control Device


Only 10 left - Selling fast

PRODUCT SKU : D25-0157-000003

PRODUCT TYPE : Industrial Controllers

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE Fanuc D25-0157-000003, also cataloged as the D25 Measurement and Control Device, operates as a dedicated hardware component for specific technical task execution within industrial automation and network platforms. The component ingests high-accuracy electrical telemetry across integrated AC current, DC current, and DC voltage physical interface nodes. By calculating waveforms from multi-range CT links and instrument loops, the module services localized digital fault recording (DFR) and real-time regulation routines over active internal processing buses.

Hardware Specifications

Parameter Specification
Model D25-0157-000003
Brand GE Fanuc
Origin Technical specifications determine factory origin
Weight Internal hardware option selection dependent
Dimensions Standard D25 series chassis envelope requirements apply
Operating Temp Industrial grade environmental classification
Power Consumption Base processor draw plus active measuring channel configuration loads
Nominal CT Input Options 1 A rms or 5 A rms
AC Measurement Range 2% to 1600% of nominal; 2% to 4200% (asymmetrical) for DFR/protection
Thermal Overload Limits 4x nominal continuous; 30x nominal for 10 seconds; 100x nominal for 1 second; 10-minute duty cycle for parameters exceeding 4x nominal
AC Accuracy Metrics Accuracy: +/-0.5% to +/-0.3% of nominal; Frequency: +/-0.03 Hz; Phase Angle: +/-0.5 deg
DC Current Ranges +/-1 mA, +/-5 mA, +/-10 mA, +/-20 mA nominal
DC Current Accuracy +/-0.10% of full scale
DC Voltage Input Span Nominal: +/-5 Vdc; Measurement range: +/-6 Vdc
DC Voltage Accuracy +/-0.05% of full scale

Profinet / EtherNet/IP Deterministic Networks Integration

The module manages input scaling through its internal analog-to-digital matrix, utilizing fixed software filtering blocks to maintain firmware flash compatibility across concurrent operating cycles. High-density I/O registers serialize the +/-20 mA DC current loops and +/-6 Vdc voltage inputs into the memory map, isolating transient electrical noise from the primary processor backplane communication channel. This architectural separation preserves deterministic communication performance, preventing host communication packet peaks from delaying the 1 ms fault-recording triggers managed by the AC protection circuits.

Frequently Asked Questions

Q: How is the 4200% asymmetrical AC current measurement range managed by the DFR firmware without causing memory overflows?

A: The onboard analog-to-digital conversion matrix reserves dedicated high-headroom registers for transient surge inputs. When an asymmetrical fault step occurs, the internal scaling algorithms automatically track the over-range parameter without impacting firmware flash compatibility or disrupting concurrent DC loop sampling.

Q: Can the CT input terminals be disconnected while the primary power lines are under load?

A: No. Disconnecting active CT loops causes high-voltage open-circuit transients that can destroy the low-burden input resistors. The secondary current paths must be externally shorted or fully isolated before servicing any analog connector blocks on the D25-0157-000003.

Field Installation Guidelines

  • Earthing and Grounding Frame: Bond the metal chassis ground screw directly to the main cabinet copper ground bus bar using a low-impedance grounding cable before routing any instrumentation lines.
  • AC Input Shielding: Run all AC current transformer connections through dedicated twisted-shielded pairs, terminating the shield grounding braid strictly at the enclosure wall plate to block inductive interference.
  • Low-Voltage Cable Trailing: Route the +/-5 Vdc voltage and low-current DC signal lines in distinct wiring ducts isolated from primary high-voltage AC switches and inductive control relay circuitry.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.