Skip to content

What are you looking for?


You may also like

745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module
745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module
745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module
745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module

745-W2-P5-G1-HI-A GE 745 Series Transformer Protection Relay Module


Only 10 left - Selling fast

PRODUCT SKU : 745-W2-P5-G1-HI-A

PRODUCT TYPE : Transformer Protection Relays

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE 745-W2-P5-G1-HI-A, also cataloged as the GE 745 Transformer Protection Relay Module, operates as a dedicated hardware component for multi-winding current differential evaluation and fault actuation within utility substation power networks.

Hardware Specifications

Parameter Specification
Model 745-W2-P5-G1-HI-A
Brand GE Multilin
Origin Canada / United States
Weight Standard Relay Unit Weight
Dimensions Standard 745 Series Chassis Profile
Operating Temp -20 - +60 deg C
Power Consumption HI Power Supply Option Dependent
Transformer Windings 2 Winding configuration (W2)
Phase CT Input 5 A secondary (P5)
Ground CT Input 1 A / 5 A secondary (G1)
Protection Elements 87T (Differential), 24 (Overexcitation), 49 (Thermal Overload)
Board Protection Conformal coating layer
Local Interface Enhanced LCD display with expanded keypad

Firmware Flash Compatibility and Processing Architecture

The module computes phase current vectors and calculates differential metrics continuously across the 2-winding network structure. Real-time calculations of Total Harmonic Distortion (THD), frequency rate-of-change, and hottest spot thermal tracking are executed via an internal floating-point processor. To preserve execution synchronization and prevent buffer underruns during sequence-of-events logging, matching upstream substation SCADA properties with verified firmware flash compatibility benchmarks across all localized processing layers is mandatory.

Frequently Asked Questions

Q: How does the dynamic CT ratio mismatch correction behave during external fault states?

A: The internal processing matrix samples phase currents and normalizes scaling parameters mathematically based on configured winding entries every half-cycle. This internal optimization eliminates the requirement for external auxiliary matching current transformers.

Q: What is the function of the conformal coating modification on this specific hardware assembly?

A: The conformal coating layer isolates surface-mount components from atmospheric moisture, airborne conductive particulates, and corrosive chemical traces, preventing parasitic trace leakage and maintaining dielectric boundary integrity.

Field Installation Guidelines

  • Chassis Grounding Connection: Attach a dedicated, low-impedance copper conductor from the rear panel safety ground lug directly to the local substation primary earth ground grid.
  • Current Transformer Termination Layout: Route all 5 A phase and ground CT secondary loops through external shorting test blocks before connecting to the terminal block to allow safe maintenance tracking.
  • Control Cable Segregation: Run all low-voltage analog signal lines through dedicated wireways isolated from the main alternating current (AC) or high-voltage direct current (DC) control power wiring to minimize electromagnetic noise coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more