Product Details

Configured for signal conversion in rotating machinery monitoring networks, the Epro CON020/91 (CON020/91 Signal Conditioner Module Driver) provides direct physical electrical execution for processing transducer inputs into standardized analog signals. The module accepts raw probe inputs and delivers either analog voltage or 4-20 mA current outputs, interfacing directly with TSI monitoring platforms to support continuous data acquisition in machinery protection applications.

Hardware Specifications

Parameter Specification
Model CON020/91
Brand Epro
Dimensions 100 mm x 22 mm x 120 mm
Operating Temp -35 to 85 deg C
Input Type Transducer Signal
Output Type Analog Voltage or 4-20 mA

Mechanical Monitoring and TSI Characteristics

The CON020/91 module is engineered to manage critical signal parameters for eddy-current probe scaling within machinery protection systems. It supports the precise adjustment of gain and offset required for gap voltage validation against -10 VDC targets, ensuring that the sensor response remains linear across the transducer's measurement range. To preserve data integrity in high-density rack configurations, the module incorporates internal cross-talk suppression and EMI immunity filters, which are required for reliable rotor dynamics analysis under varying load and speed conditions.

Frequently Asked Questions (FAQ)

Q: Can the CON020/91 be hot-swapped while the machinery is operating?

A: Module removal or replacement during active operation depends on the backplane architecture and system configuration. Ensure the I/O channel is inhibited in the monitoring software to prevent a false trip or alarm signal before extracting the module.

Q: Is the 4-20 mA output isolated from the power supply ground?

A: The module is designed for industrial integration where loop isolation is required. Consult the system interconnection diagram to confirm if the output stage requires an external isolator to prevent ground loops between the module and the destination input card.

Field Installation Guidelines

  1. Mount the module on a standard DIN rail or designated rack chassis, ensuring the mechanical locking clip is fully engaged.
  2. Terminate signal input cabling using shielded, twisted-pair wire to minimize electromagnetic interference (EMI) ingress.
  3. Verify that the shield drain wire is bonded to the cabinet earth ground at the rack entry point only to avoid ground loops.
  4. Set the internal jumpers or configuration switches to match the desired output mode (voltage or current) before applying 24 VDC power.
  5. Confirm stable signal output at the terminal block using a calibrated multimeter prior to validating the sensor gap voltage at the probe tip.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more