Skip to content

What are you looking for?


You may also like

AN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ GatewayAN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ GatewayAN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ Gateway
AN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ Gateway
AN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ Gateway
AN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ Gateway

AN-X2-AB-DHRIO | ProSoft Ethernet/IP to Remote I/O & DH+ Gateway


Only 10 left - Selling fast

PRODUCT SKU : AN-X2-AB-DHRIO

PRODUCT TYPE : Communication Gateway Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The ProSoft Technology AN-X2-AB-DHRIO gateway module provides seamless integration between modern Ethernet/IP networks and legacy Allen Bradley Remote I/O (RIO) and Data Highway Plus (DH+) systems. Designed for ControlLogix and CompactLogix environments, this communication module enables connectivity with PLCs, SLC 500 controllers, PanelView HMIs, drives, and Flex I/O adapters, ensuring reliable interoperability across mixed-generation automation systems.

Technical Specifications

  • Manufacturer: ProSoft Technology (Allen Bradley compatible)

  • Part Number: AN-X2-AB-DHRIO

  • Product Line: ControlLogix

  • Product Type: Communication Gateway Module

  • Weight: 0.69 lbs (≈ 0.31 kg)

  • Baud Rate Range: 57.6 to 230.4 kbaud

  • Supported Protocols: Ethernet/IP, Remote I/O (RIO), Data Highway Plus (DH+)

  • Rack Number Range: 0 to 76 octal

  • Ports:

    • 1 × 10/100 Mbps Ethernet/IP (RJ-45)

    • 1 × RIO/DH+ port

  • Power Supply: 24 VDC nominal

  • Voltage: 12 VDC

  • Current Consumption: 100 mA typical, 200 mA max

  • Power Dissipation: 2.4 W

  • Mounting Options: DIN rail or desktop installation

  • Supported Ethernet Devices: ControlLogix, CompactLogix

  • Supported RIO/DH+ Devices: PLC, SLC 500, PanelView HMIs, Drives, Flex I/O adapters

  • Maximum Supported Modules:

    • 32 RIO racks

    • 4 Ethernet/IP drives

    • 8 PanelView HMIs

  • Operating Temperature: 0–50 °C (32–122 °F)

  • Storage Temperature: -40–85 °C (-40–185 °F)

Application Scenarios

This gateway is ideal for facilities upgrading to Ethernet/IP while maintaining legacy RIO and DH+ devices. It allows seamless communication between modern controllers and older hardware, reducing downtime and simplifying migration strategies.

Comparison with Similar Modules

  • AN-X2-AB-DHRIO: Supports Ethernet/IP, RIO, and DH+ with broad device compatibility.

  • Other ProSoft gateways: May support only one protocol or limited device types, making them less versatile for mixed environments.

FAQ

Q: Can this gateway connect both Ethernet/IP and DH+ devices simultaneously?  A: Yes, it supports concurrent communication across Ethernet/IP and DH+ networks.

Q: How many PanelView HMIs can be connected?  A: Up to eight PanelView terminals can be supported on the same network.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more