Skip to content

What are you looking for?


You may also like

ABB FI820F 3BDH000031R1 Communication ModuleABB FI820F 3BDH000031R1 Communication ModuleABB FI820F 3BDH000031R1 Communication Module
ABB FI820F 3BDH000031R1 Communication Module
ABB FI820F 3BDH000031R1 Communication Module
ABB FI820F 3BDH000031R1 Communication Module

ABB FI820F 3BDH000031R1 Communication Module


Only 10 left - Selling fast

PRODUCT SKU : FI820F 3BDH000031R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BDH000031R1, also cataloged as the 3BDH000031R1 Communication Module, operates as a dedicated hardware component for dual-channel serial communication execution within ABB control platforms. It processes Modbus protocol data streams across two independent channels, interfacing directly between field instrumentation and the controller backplane while providing galvanic protection across serial line paths.

Hardware Specifications

Parameter Specification
Model 3BDH000031R1
Brand ABB
Origin Standard Industrial
Weight 0.145 kg
Dimensions 125 x 155 x 28 mm
Operating Temp -40 to +70 deg C
Power Consumption 2.5 W
Power Supply Voltage 24 VDC
Communication Protocol Modbus
Number of Channels 2
Communication Speed Up to 192 kbps
Isolation Voltage 2500 V
Storage Temperature -40 to +85 deg C
Humidity 0 to 95% RH (non-condensing)

Galvanic Isolation and Firmware Flash Compatibility

The 3BDH000031R1 communication module incorporates 2500 V galvanic isolation between field device terminals and internal controller electronics to suppress common-mode electrical transients and ground loops. Channel-to-channel communication routines execute over two independent serial interfaces operating at speeds up to 192 kbps. Integrated firmware flash storage maintains protocol stack parameter configurations across system boot cycles, ensuring deterministic Modbus packet parsing without backplane execution delays.

Frequently Asked Questions

Q: What level of electrical protection is provided on the serial communication channels?

A: The module provides 2500 V isolation between connected field devices and the system controller to shield internal hardware from high-voltage faults and transients.

Q: Can the two serial channels operate simultaneously under different baud rates?

A: Both channels operate independently up to 192 kbps, allowing asynchronous Modbus communication across separate serial line segments.

Q: How is power delivered to the 3BDH000031R1 communication module?

A: The module operates on a standard 24 VDC external power supply with a maximum power consumption rating of 2.5 W.

Field Installation Guidelines

  1. Mount the module securely on a standard DIN rail inside the control cabinet using the integral retention mechanism.
  2. Disconnect the 24 VDC power supply before wiring field communication terminals to avoid short circuits.
  3. Route serial communication cabling in separate wire ducts away from high-voltage AC power lines and motor drives.
  4. Maintain a 360-deg braid shield ground connection at the cabinet entry plate to maximize noise immunity.
  5. Verify that operating ambient temperatures inside the enclosure remain within the -40 to +70 deg C specification.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more