Skip to content

What are you looking for?


You may also like

Allen Bradley 1786-TPYS ControlNet Coaxial Straight Y-TapAllen Bradley 1786-TPYS ControlNet Coaxial Straight Y-TapAllen Bradley 1786-TPYS ControlNet Coaxial Straight Y-Tap
Allen Bradley 1786-TPYS ControlNet Coaxial Straight Y-Tap
Allen Bradley 1786-TPYS ControlNet Coaxial Straight Y-Tap
Allen Bradley 1786-TPYS ControlNet Coaxial Straight Y-Tap

Allen Bradley 1786-TPYS ControlNet Coaxial Straight Y-Tap


Only 10 left - Selling fast

PRODUCT SKU : 1786-TPYS

PRODUCT TYPE : ControlNet Network Taps

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1786-TPYS functions as a critical connection point within a ControlNet coaxial media system. This Y-Tap allows a node—such as a PLC, I/O chassis, or HMI—to connect to the trunk line without interrupting the signal flow to other devices. We offer this unit as 100% Brand New, ensuring factory-spec signal impedance and physical integrity for high-speed deterministic networks.

Technical Specifications

The 1786-TPYS integrates rugged industrial housing with precision-tuned internal circuitry to maintain network balance.

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Part Number 1786-TPYS
Network Type ControlNet
Tap Style Y-Tap (Straight)
Integrated Cable Length 1 Meter (3.28 ft)
Connector Type BNC (Coaxial)
Category Machine Control / PLC Communication
Weight 0.45 lbs (0.20 kg)
Housing Industrial-grade polymer

Engineering Advantages

  • Non-Intrusive Node Integration: The 1786-TPYS allows for the addition or removal of nodes from the ControlNet network without breaking the trunk line continuity. This design prevents system-wide downtime during hardware maintenance or expansion.

  • Optimized Signal Path: The "Straight" configuration and fixed 1-meter drop cable eliminate the guesswork of cable trimming. It provides a pre-measured, low-attenuation path that ensures your device meets the required signal-to-noise ratio for 5 Mbps data rates.

  • Passive Reliability: Because the Y-Tap operates as a passive component, it requires no external power. It maintains network impedance (75 Ω) through high-quality internal coupling, effectively preventing signal reflections that cause packet loss.

  • Rapid Deployment in Cabinets: The compact form factor excels in crowded PLC racks. The 1-meter pigtail provides sufficient reach to connect the trunk line mounted on the enclosure wall to a controller located in the center of the rack.

FAQs

  • What is the difference between a "Straight" Y-Tap and a "Right-Angle" Tap?

    The 1786-TPYS features a straight cable exit, which suits deep enclosures where the cable can run directly outward from the tap. Right-angle versions (like the 1786-TPS) assist in shallow cabinets where bend radius constraints require the cable to exit parallel to the mounting surface.

  • Does the 1-meter cable length affect network distance calculations?

    Yes. When calculating your total ControlNet segment length, you must include the 1-meter drop cable of each 1786-TPYS. Exceeding the maximum allowed segment length without a repeater can lead to timing errors.

  • Can I shorten the integrated 1-meter BNC cable?

    We strongly advise against modifying the integrated drop cable. The factory-sealed BNC connection ensures electromagnetic shielding. Cutting or re-terminating the cable risks introducing impedance mismatches and EMI vulnerabilities.

  • How do I terminate the unused ports on a 1786-TPYS?

    If you install a tap but do not yet have a node to connect, you must install a 75 Ω terminator (1786-XT) on the unused BNC port. This prevents signal reflections from crashing the entire network segment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more