Skip to content

What are you looking for?


You may also like

P0916DW Foxboro DINFBM Cable TerminalP0916DW Foxboro DINFBM Cable TerminalP0916DW Foxboro DINFBM Cable Terminal
P0916DW Foxboro DINFBM Cable Terminal
P0916DW Foxboro DINFBM Cable Terminal
P0916DW Foxboro DINFBM Cable Terminal

P0916DW Foxboro DINFBM Cable Terminal


Only 10 left - Selling fast

PRODUCT SKU : P0916DW

PRODUCT TYPE : Cable Assemblies

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for signal routing and inter-module connection within Foxboro I/A Series distributed control architectures, the Foxboro P0916DW (P0916DW DINFBM Cable Terminal) provides direct physical/electrical execution for DIN-rail mounted Fieldbus Module (DINFBM) subassemblies.

Hardware Specifications

Parameter Specification
Model P0916DW
Brand Foxboro
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive component (0 W active dissipation)
Cable Type DINFBM Cable and Terminal Assembly
System Compatibility Foxboro I/A Series DIN-rail Mounted FBMs

4-20 mA HART Loop Protocol and Channel Isolation

Operating within Foxboro I/A Series DCS environments, the cable and terminal assembly maintains precise conductor impedance and insulation properties to support uncompromised communication across analog and discrete loops. The internal multi-conductor bundle incorporates continuous metallic shielding to mitigate electromagnetic interference (EMI) and radio frequency interference (RFI) from adjacent plant infrastructure. Proper shield termination at the chassis ground studs is mandatory to preserve common-mode noise rejection and ensure accurate signal transmission alongside active 4-20 mA HART loop protocol wiring runs.

Frequently Asked Questions

Q: Can the P0916DW cable assembly be disconnected while the DINFBM module and baseplate are energized?

A: No. Disconnecting interface cables while system power is active can corrupt data transmission, trigger communication faults, or cause unexpected I/O drops across the I/A Series node. System power must be isolated before performing cable maintenance.

Q: How should the cable be routed to prevent interference inside high-density control cabinets?

A: The cable should be routed through dedicated wire management channels away from high-voltage AC power lines and variable frequency drive cables to prevent radiated noise coupling into signal lines.

Field Installation Guidelines

  • Verify that system power to the connected DINFBM modules and terminal blocks is completely de-energized and locked out prior to handling the cable connectors.
  • Align connector polarization pins carefully with the module receptacle to prevent bent pins or housing misalignment during insertion.
  • Secure all retaining screws or locking mechanisms firmly to specified torque limits to withstand heavy industrial vibration environments.
  • Inspect cable insulation and shielding integrity before final placement in the cabinet raceway.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more