The ICS Triplex PS01-A, also cataloged as the PS01-A Power Supply Module, operates as a dedicated hardware component for power distribution within ICS Triplex Trusted safety instrumented systems. Accepting a nominal 24 VDC input and delivering a regulated 24 VDC output, this unit powers critical processor chassis rails and expansion backplanes across an operating temperature range of -40 to +85 deg C (-40 to +185 deg F).

Hardware Specifications

Parameter Specification
Model PS01-A
Brand ICS Triplex
Origin United Kingdom
Weight 6.5 kg (14.33 lbs)
Dimensions 112 mm x 70 mm x 123 mm
Operating Temp -40 to +85 deg C (-40 to +185 deg F)
Storage Temp -40 to +85 deg C (-40 to +185 deg F)
Humidity Range 10% to 90% RH non-condensing
Power Consumption Passive Power Conditioning (Internal Dissipation Dependent on Load)
Input Voltage 24 VDC
Output Voltage 24 VDC
System Compatibility ICS Triplex Safety Instrumented Systems (SIS)

Functional Safety and Triple Modular Redundancy

The ICS Triplex PS01-A power supply module is engineered to support SIL3 certification requirements in high-integrity automation systems. Integrated within a triple modular redundancy (TMR) 2oo3 architecture, the module incorporates robust galvanic isolation between primary power input terminals, system logic circuitry, and chassis earth ground. Internal fault-detection diagnostic logic monitors input/output voltage levels continuously, driving the power bus into a defined fail-safe state execution upon detecting persistent over-voltage or under-voltage conditions without disrupting parallel active power channels.

Frequently Asked Questions

Q: Can the PS01-A power supply module be hot-swapped while the system is actively operating?

A: Yes, in dual or N+1 redundant power chassis configurations, a faulted PS01-A module can be unseated and replaced without shutting down power to the system backplane logic.

Q: What is the primary purpose of internal galvanic isolation within the PS01-A unit?

A: Galvanic isolation prevents field-side electrical surges and ground loop currents from propagating to the main processor backplane, maintaining system safety integrity.

Field Installation Guidelines

  1. Slide the PS01-A module into the dedicated power supply chassis slot along the guide rails until fully seated.
  2. Engage and tighten top and bottom module retaining screws to secure mechanical grounding to the rack chassis.
  3. Wire the 24 VDC primary power supply leads to the designated screw terminals, observing strict polarity matching.
  4. Connect the main protective earth (PE) grounding conductor to the chassis earth terminal using heavy-gauge wiring prior to energizing the module.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more