Skip to content

What are you looking for?


You may also like

TRICONEX 3000110-380 2553-8 24V Digital Input Terminal AssemblyTRICONEX 3000110-380 2553-8 24V Digital Input Terminal AssemblyTRICONEX 3000110-380 2553-8 24V Digital Input Terminal Assembly
TRICONEX 3000110-380 2553-8 24V Digital Input Terminal Assembly
TRICONEX 3000110-380 2553-8 24V Digital Input Terminal Assembly
TRICONEX 3000110-380 2553-8 24V Digital Input Terminal Assembly

TRICONEX 3000110-380 2553-8 24V Digital Input Terminal Assembly


Only 10 left - Selling fast

PRODUCT SKU : 3000110-380

PRODUCT TYPE : Termination Panels

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-integrity safety-instrumented system applications, the TRICONEX 3000110-380, also cataloged as the 3000110-380 24V Digital Input Terminal Assembly, provides direct physical/electrical execution. The hardware manages field-side discrete signal termination for 24 V digital input loops, routing sensor inputs across redundant termination architectures within Triconex safety instrumented platforms.

Hardware Specifications

Parameter Specification
Model 3000110-380 / 2553-8
Brand TRICONEX
Origin Standard Manufacturing Facility
Weight 7.00 lbs (3.18 kg)
Dimensions Standard Termination Panel Enclosure
Operating Temp Standard Industrial Range (0 deg C to 60 deg C)
Power Consumption Passive Termination Panel (0 W)
Module Type 24 V Digital Input Terminal Assembly
System Compatibility Triconex Safety Instrumented System (SIS)
Signal Interface 24 V Discrete Input Field Termination

SIL3 Certification and Triple Modular Redundancy Architecture

Engineered for high-integrity safety applications, this terminal assembly supports SIL3 certification compliance by routing redundant discrete input loops across triple modular redundancy (TMR) 2oo3 architecture legs. Internal circuit layouts incorporate rigorous galvanic isolation and fail-safe state execution pathways, ensuring that single-point faults or field-side wiring transients do not compromise emergency shutdown logic or trigger spurious trips within safety-critical loops.

Frequently Asked Questions

Q: Does the 3000110-380 termination assembly require external power distribution for field sensors?

A: Yes, external 24 V power supplies must be routed through the designated panel terminals to energize field-side discrete input devices connected to the safety system.

Q: Can interface cables be disconnected from the terminal assembly while the Triconex system is energized?

A: Uncoupling pre-formed inter-cabinet or module interface cables under live operating conditions is restricted to prevent open-circuit faults, signal spikes, or momentary channel degradation on active safety loops.

Field Installation Guidelines

  • Mount the termination panel securely onto standard DIN rails or structural backplane standoffs inside an approved safety-rated instrumentation cabinet.
  • Ensure all field signal shield drain wires are terminated continuously to the integrated ground busbar to maintain noise immunity against electromagnetic interference.
  • Verify that incoming loop voltages and signal types strictly match system configuration requirements prior to energizing field circuits.
  • Maintain adequate physical separation between safety-instrumented signal wiring and high-voltage power conduits to prevent cross-regulated attenuation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more