Overview

The Allen-Bradley 1746-NO4I is a precision analog output module designed for SLC 500 PLC systems. It provides four independent analog output channels with high-resolution 14-bit conversion, fast update time, and reliable current output for industrial control applications.

Technical Specifications

  • Model / Part Number: 1746-NO4I

  • Brand: Allen-Bradley

  • Product Type: Analog Output Module / SLC 500 Module

  • Number of Outputs: 4 independent channels

  • Output Current Range: 0 to +20 mA

  • Full Scale Output: 21 mA

  • Overrange Capability: 5% (0 to +21 mA minus 1 LSB)

  • Current Output Coding: 0 to +32764

  • Resolution: 14 bits

  • Update Time: 512 microseconds

  • Step Response Time: 2.5 milliseconds

  • Backplane Current: 5 V: 55 mA, 24 VDC: 195 mA

  • Weight: 1.0 lbs (0.45 kg)

  • Series: SLC 500

Application Scenarios

  • Precision control of actuators and valves in process automation

  • Signal generation for analog control loops in SLC 500 PLC networks

  • Industrial monitoring systems requiring fast analog output response

  • Replacement or expansion of existing Allen-Bradley SLC 500 analog outputs

Comparison with Similar Models

  • 1746-NO4I vs 1746-NO4V: The NO4I provides isolated analog outputs with 14-bit resolution, while the NO4V offers voltage outputs for systems needing 0–10 V control signals.

  • SLC 500 Analog Modules: NO4I is optimized for fast response and high-precision current control, suitable for critical loop applications.

FAQs

Q1: What is the maximum update speed for the outputs?
The 1746-NO4I has an update time of 512 microseconds per channel, enabling rapid analog signal changes.

Q2: Can this module be used in existing SLC 500 racks?
Yes, it is fully compatible with standard SLC 500 backplanes and requires only the specified backplane current.

Q3: What is the resolution and accuracy of the output?
The module features 14-bit resolution, providing precise current outputs with minimal error over the full 0–20 mA range.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more