Skip to content

What are you looking for?


You may also like

Allen-Bradley 1746-IH16 SLC 500 Digital DC Input ModuleAllen-Bradley 1746-IH16 SLC 500 Digital DC Input ModuleAllen-Bradley 1746-IH16 SLC 500 Digital DC Input Module
Allen-Bradley 1746-IH16 SLC 500 Digital DC Input Module
Allen-Bradley 1746-IH16 SLC 500 Digital DC Input Module
Allen-Bradley 1746-IH16 SLC 500 Digital DC Input Module

Allen-Bradley 1746-IH16 SLC 500 Digital DC Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1746-IH16

PRODUCT TYPE : Digital DC Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1746-IH16 functions as a high-density discrete input interface for the Allen-Bradley SLC 500 chassis. It provides 16 isolated channels designed specifically to sense high-voltage DC signals (125VDC nominal). This module bridges the gap between high-voltage field devices and the low-voltage logic of the PLC processor. Despite the manufacturer’s discontinued status, we offer 100% Brand New, original units to ensure the continued operation of your mission-critical control systems.

Technical Specifications

This module features a robust hardware profile designed for heavy-duty switching environments.

Feature Specification
Number of Inputs 16 Channels
Voltage Category 125V DC
Operating Voltage Range 90–146V DC
Backplane Current (5V) 0.085 A
Backplane Current (24V) 0.000 A
Signal Delay (Max) 8ms (On to Off) / 8ms (Off to On)
Weight 1.00 lbs (0.45 kg)

Engineering Advantages

  • High-Voltage Direct Sensing: The 1746-IH16 eliminates the need for interposing relays when monitoring 125VDC circuits. This simplifies cabinet wiring, reduces points of failure, and saves significant DIN rail space.

  • Enhanced Noise Immunity: The high-voltage threshold inherently rejects low-level electromagnetic interference (EMI) and crosstalk from adjacent AC cables, ensuring signal integrity in electrically "noisy" power plants or substations.

  • Seamless Backplane Integration: The module slides directly into any available slot in a 1746 chassis. It draws minimal current from the SLC backplane, allowing engineers to maximize the I/O density without overloading the power supply.

  • Rapid Fault Recovery: By utilizing 100% Brand New factory-sealed modules, maintenance teams avoid the risks associated with aged capacitors or degraded terminal blocks found in used equipment, ensuring immediate system restoration.

FAQs

  • Can I use the 1746-IH16 in a remote I/O rack?

    Yes. The module operates flawlessly in any local SLC 500 chassis or a remote 1747-ASB/ACNR adapter-linked rack, provided the backplane supports 1746 I/O.

  • What is the primary difference between this and standard 24VDC modules?

    The 1746-IH16 targets high-voltage utility and power generation applications. It requires a minimum of 90VDC to register an "On" state, whereas standard modules trigger at much lower thresholds.

  • Does this module require a separate external power supply for the inputs?

    Yes. You must provide the 125VDC field power to the input terminals. The module only draws logic-side power (5VDC) from the PLC backplane.

  • Is this unit compatible with the SLC 5/01, 5/02, 5/03, 5/04, and 5/05 processors?

    Absolutely. The 1746-IH16 maintains universal compatibility across the entire SLC 500 processor range, ensuring a versatile fit for any legacy system upgrade or repair.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more