Skip to content

What are you looking for?


You may also like

Allen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen TerminalAllen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen TerminalAllen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen Terminal
Allen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen Terminal
Allen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen Terminal
Allen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen Terminal

Allen Bradley 2711P-T10C6D2 PanelView Plus 1000 Color Touchscreen Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T10C6D2

PRODUCT TYPE : Touchscreen Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711P-T10C6D2 serves as a high-performance Human-Machine Interface (HMI) designed for large-scale application monitoring and control. Featuring a 10.4-inch color display, this PanelView Plus 1000 terminal translates complex machine data into actionable visual insights for operators. We supply this unit as 100% Brand New and Factory Original, providing a critical replacement solution for facilities maintaining robust legacy communication architectures.

Technical Specifications

The following table details the core hardware capabilities of the 2711P-T10C6D2:

Feature Specification
Display Size 10.4-inch Color Graphics
Input Method Analog Resistive Touchscreen
Communication Ports DH+ (Data Highway Plus) and DH-485
Input Voltage 18-32 VDC (24VDC Nominal)
User Memory 128 MB RAM
Replacement Backlight 2711P-RL10C2
Compatible Cables 1770-CD / 1761-CBL-ASO3
Weight 5.94 lbs (2.69 kg)
Supported Series Series A, B, C, D, and F

Engineering Advantages

  • Legacy Protocol Optimization: This terminal features native DH+ and DH-485 ports. This hardware configuration allows direct integration into existing PLC-5 or SLC 500 networks without the latency or complexity of external protocol converters.

  • DC Power Efficiency: The unit operates on a 18-32 VDC range. This matches standard industrial battery backups and 24VDC power supplies, reducing the risk of AC-line noise interference and improving overall system stability during brownouts.

  • High-Impact Touch Interface: The 10.4-inch analog resistive touchscreen provides a large target area for operator inputs. The surface resists common industrial contaminants, ensuring input accuracy even when operators wear gloves or work in environments with airborne particulates.

  • Modular Hardware Design: The PanelView Plus 1000 series utilizes a separate logic module and display module. This architecture simplifies field maintenance; if the display sustains physical damage, you can swap the screen while retaining the existing logic and application data.

FAQs

  • Is this 2711P-T10C6D2 unit a refurbished product?

    No. We guarantee this unit is 100% Brand New. It ships in its original manufacturer’s packaging with factory seals intact, ensuring zero prior hours of field operation.

  • Can I use this terminal to replace an older Series A unit?

    Yes. The 2711P-T10C6D2 supports Series A through F. It maintains backward compatibility with legacy applications, though you should verify that your FactoryTalk View ME project matches the firmware revision of the hardware.

  • How do I handle the "Discontinued" status for my facility?

    Sourcing a Brand New unit allows you to avoid costly panel redesigns and software migrations. This terminal drops directly into your existing cutout and connects to your DH+ network, extending the lifecycle of your current automation assets.

  • What are the primary installation requirements?

    Ensure a clean panel cutout that meets the NEMA/IP rating requirements. Use the provided mounting clips to apply even pressure across the gasket; this prevents moisture ingress and stabilizes the 5.94 lb unit against machine vibrations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more