Product Description

Allen-Bradley PanelView 5510 Graphic Terminal – Model: 2715-T10CD  The 2715-T10CD is a touchscreen-only operator interface terminal from the Allen-Bradley PanelView 5500 series. Designed for industrial visualization, it provides a 10.4-inch color display with Ethernet/IP communication, robust memory capacity, and reliable performance for machine-level monitoring and control.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Product Line: PanelView 5500

  • Model: 2715-T10CD

  • Type: Graphic Operator Terminal

  • Display Size: 10.4 inches

  • Display Type: Color graphics

  • Input Method: Touchscreen only

  • Touchscreen Technology: Analog resistive

  • Input Voltage Range: 18–30 VDC

  • Nominal Input Voltage: 24 VDC

  • Memory Capacity: 250 MB

  • Communication Protocols: Ethernet/IP

  • Weight: 5.19 lbs (2.35 kg)


Application Scenarios

  • Machine-level operator interface for industrial automation

  • Process visualization requiring mid-size color displays

  • Systems requiring Ethernet/IP communication for integration

  • Applications needing touchscreen-only terminals for simplified operator input

FAQ

Q: What is the display size of the 2715-T10CD?  A: It features a 10.4-inch color display.

Q: What type of input does the terminal support?  A: It is touchscreen-only, using analog resistive technology.

Q: What communication protocol is supported?  A: The terminal supports Ethernet/IP communication.

Q: What is the memory capacity?  A: It includes 250 MB of memory for applications and data.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more