Skip to content

What are you looking for?


You may also like

2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash
2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash
2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash
2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash

2711P-RW7 | Allen Bradley | PanelView Plus CE 256MB Internal CompactFlash


Only 10 left - Selling fast

PRODUCT SKU : 2711P-RW7

PRODUCT TYPE : Internal CompactFlash

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711P-RW7 serves as a high-performance internal storage solution specifically engineered for PanelView Plus CE logic modules. This 256 MB CompactFlash card functions as the core system drive, housing both the open Windows CE operating system and the FactoryTalk View Machine Edition (ME) runtime environment. It enables advanced HMI functionalities, allowing users to execute desktop-style applications and sophisticated data handling tasks directly on the factory floor interface.

Technical Specifications

Feature Details
Manufacturer Allen Bradley / Rockwell Automation
Part Number 2711P-RW7
Storage Capacity 256 MB
Memory Type Internal CompactFlash (Industrial Grade)
Operating System Windows CE (Open Version)
Pre-loaded Software FactoryTalk View Machine Edition (ME)
Compatibility PanelView Plus CE Logic Modules
Condition 100% Brand New Original

Engineering Advantages

  • Integrated Software Ecosystem: This module eliminates the complexity of manual OS installation. It arrives pre-configured with Windows CE and FactoryTalk View ME, allowing engineers to bypass software setup and proceed directly to application deployment.

  • Enhanced System Flexibility: Unlike standard PanelView units, the 2711P-RW7 enables an "Open" Windows CE environment. This allows the HMI to run third-party viewers, terminal services, and custom scripts, effectively bridging the gap between a standard HMI and an Industrial PC.

  • Industrial-Grade Endurance: The CompactFlash architecture provides high vibration and shock resistance. It withstands the rigorous thermal cycles found in industrial control cabinets, ensuring data integrity where standard consumer-grade flash media fails.

  • Rapid Disaster Recovery: The 2711P-RW7 acts as a complete system clone. In the event of a logic module failure, maintenance teams simply swap the card into a new module to restore full system operation in minutes, drastically reducing costly downtime.

FAQs

  • Is this 2711P-RW7 card ready for immediate use?

    Yes. Every unit is 100% Brand New and comes pre-loaded with the necessary Windows CE OS and FactoryTalk View ME software. You can install it directly into a compatible PanelView Plus CE logic module.

  • Can I use this card in a standard PanelView Plus (Non-CE) module?

    No. The 2711P-RW7 specifically supports the CE version of the logic modules. Standard modules use different internal firmware and memory configurations.

  • Does this card include the license for FactoryTalk View ME?

    The card contains the software runtime environment. You must ensure your logic module or system configuration includes the appropriate activation for the FactoryTalk View ME station.

  • What is the benefit of the "Open" Windows CE version on this card?

    The open version provides access to the Windows desktop, file manager, and control panel. This allows you to manage files locally, use web browsers, or run custom executable files that standard HMIs cannot support.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more