Skip to content

What are you looking for?


You may also like

22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive
22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive
22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive
22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive

22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive


Only 10 left - Selling fast

PRODUCT SKU : 22C-B024N103

PRODUCT TYPE : Adjustable Frequency AC Drive

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 22C-B024N103 functions as a high-performance, adjustable frequency AC drive within the PowerFlex 400 manufacturing family. Engineers design this hardware speed controller primarily to regulate variable torque loads, such as heavy-duty industrial fan systems and centrifugal fluid pumps.

The device dynamically modulates voltage and frequency lines to match motor output with real-time operational demand, slashing facility energy overhead. We distribute this motor controller exclusively as a 100% brand new, original factory-sealed unit, which guarantees intact copper bus bars, virgin IGBT power modules, uncompromised internal capacitor banks, and original factory-certified firmware.

Technical Specifications

The table below displays the electrical parameters, input-output capacities, and mechanical metrics of the 22C-B024N103 variable frequency drive:

Parameter Performance & Industrial Power Rating
Manufacturer Allen-Bradley / Rockwell Automation
Part Number 22C-B024N103
UPC Barcode 820919234040
Product Line PowerFlex 400 Drive Platform
Product Type Adjustable Frequency AC Drive (VFD)
Input Phase Configuration 3-Phase Phase Configuration
Input Voltage Window 200V AC Minimum to 240V AC Maximum
Operational Supply Frequency 50 Hz to 60 Hz
Input Current Rating 26.1 Amps
Output Voltage Range 0V to 230V AC (Three-Phase Adjustable)
Continuous Output Current 24.0 Amps
Power Capacity Rating 5.5 kW (Kilowatts)
Total Apparent Power 10.9 kVA
Displacement Power Factor 0.98 (Highly Efficient Grid Power Draw)
Net Hardware Weight 8.00 lbs (3.63 kg)

Engineering Advantages

  • Trims Cabinet Footprint via Zero-Stack Side-by-Side Mounting: The mechanical enclosure utilizes an efficient internal thermal cooling path that vents exhaust gases straight out the top of the chassis. This thermal flow allows installers to pack multiple drives adjacent to each other on a single backplate with zero structural space gaps, eliminating precious lateral inches inside tightly packed electrical enclosures.

  • Eliminates Harmonic Current Disruption with an Efficiency Rating of 0.98: The internal input rectifier circuit architecture delivers a robust 0.98 displacement power factor under full motor loads. This clean power draw prevents severe harmonic feedback from travelling backward onto the main plant transformers, protecting adjacent logic boards and sensitive weighing sensors from power-line noise errors.

  • Simplifies HVAC Integration with Embedded Automation Protocols: The microprocessor features native, onboard industrial communication protocols right on the control terminals. This communication interface gives the drive the ability to interlock smoothly into building automation networks without requiring costly external communications cartridges.

FAQs

  • Can this drive operate a standard 3-phase AC motor if the local utility grid only supplies 1-phase power?

    No. The 22C-B024N103 requires a balanced 3-phase input supply voltage between 200V and 240V AC to satisfy its internal phase monitoring hardware and handle the 26.1 Amp nominal input current requirement. Attempting to feed single-phase lines into this specific model triggers an immediate input phase-loss fault condition, locking out the output firing circuit to safeguard internal rectifiers.

  • What proper spacing guidelines ensure long-term thermal survival inside unventilated enclosures?

    While the drive supports tight side-by-side positioning with adjacent PowerFlex units, field technicians must preserve minimum vertical clearance spaces to allow proper convection airflow. Maintain at least 4.7 inches (120 mm) of unobstructed space above and below the drive housing, and verify that the ambient temperature of the surrounding air stays under 50 degrees Celsius.

  • What shielding techniques block high-frequency output EMI from disrupting local analog signals?

    Technicians must run a continuous, four-conductor shielded motor cable from the U, V, and W drive terminals straight to the motor terminal box. Ground the cable shield firmly at both the drive enclosure's internal chassis ground ground bar and the motor frame ground lug using heavy brass grounding clamps to safely drain away radio-frequency electrical noise before it interferes with surrounding low-voltage 4-20mA sensor circuits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. PAC: Navigating Selection in Modern Industrial Automation

PLC vs. PAC: Navigating Selection in Modern Industrial Automation

Selecting the right controller is a fundamental decision in industrial automation. While the lines between Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC) often blur, understanding their core architectural differences is essential for system reliability. Both controllers serve as the brain of control systems, yet their specific capabilities dictate their suitability for various factory automation tasks.

Read more
Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

Transforming Textile Manufacturing: The Strategic Integration of Industrial Automation and AI

The textile industry stands at a critical technological crossroads. Legacy operations must now embrace digital transformation to remain competitive in a global market. By integrating advanced industrial automation—ranging from PLC-controlled machinery to sophisticated AI-driven analytics—manufacturers can significantly boost productivity, minimize material waste, and elevate overall product quality.

Read more
Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

Navigating Industrial Communication Protocols: A Technical Guide for Modern PLCs

In the realm of industrial automation, the Programmable Logic Controller (PLC) serves as the brain of the factory floor. However, its true power is unlocked through robust communication protocols. These digital pathways ensure seamless data exchange between controllers, sensors, and enterprise-level management systems.

Read more