Product Description

The MVI56-MCMR module from ProSoft Technology is a Modbus communication interface designed for Allen Bradley ControlLogix systems. This version features a reduced data block, making it suitable for applications that require smaller memory mapping while maintaining full Modbus RTU and ASCII communication capabilities.

Key Specifications

  • Manufacturer: ProSoft Technology / Allen Bradley

  • Model: MVI56-MCMR

  • Part Number: MVI56-MCMR

  • Product Type: Modbus Communication Module (Reduced Data Block)

  • Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Shock Resistance: 30 g operational, 50 g non-operational

  • Vibration Resistance: 5 g, 10–150 Hz

  • Relative Humidity: 5–95% non-condensing

  • Configuration Port (CFG): RJ45 (DB-9M adapter supplied), RS-232 only

  • Communication Parameters:

    • Baud Rate: 110–115,200 baud

    • Stop Bits: 1 or 2

    • Data Size: 7 or 8 bits

    • Parity: None, Even, Odd

    • RTS Timing Delay: 0–65,535 ms

  • Modbus Modes: RTU (binary with CRC-16) and ASCII (with LRC error checking)

  • Floating Point Support: Enron, Daniel®, and other implementations supported

  • Shipping Weight: 2 kg

Core Features

  • Reduced data block design for optimized memory usage

  • Full support for Modbus RTU and ASCII communication modes

  • Configurable communication parameters for flexible integration

  • Floating point data handling with industry-standard implementations

  • Diagnostic LED indicators for monitoring module status

Application Scenarios

  • Integration of Modbus devices into ControlLogix systems with limited memory requirements

  • SCADA and distributed control systems requiring Modbus RTU or ASCII communication

  • Industrial automation setups needing configurable communication parameters

FAQ

  • Q: What distinguishes the MVI56-MCMR from the MVI56-MCM?  A: The MCMR version uses a reduced data block, making it suitable for applications with smaller memory requirements.

  • Q: Which Modbus modes are supported?  A: Both RTU (binary with CRC-16) and ASCII (with LRC error checking).

  • Q: Does the module support floating point data?  A: Yes, including Enron and Daniel-style implementations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more