Product Description

The MVI56-MCMR module from ProSoft Technology is a Modbus communication interface designed for Allen Bradley ControlLogix systems. This version features a reduced data block, making it suitable for applications that require smaller memory mapping while maintaining full Modbus RTU and ASCII communication capabilities.

Key Specifications

  • Manufacturer: ProSoft Technology / Allen Bradley

  • Model: MVI56-MCMR

  • Part Number: MVI56-MCMR

  • Product Type: Modbus Communication Module (Reduced Data Block)

  • Backplane Current Load: 800 mA @ 5 VDC, 3 mA @ 24 VDC

  • Operating Temperature: 0–60°C (32–140°F)

  • Storage Temperature: –40–85°C (–40–185°F)

  • Shock Resistance: 30 g operational, 50 g non-operational

  • Vibration Resistance: 5 g, 10–150 Hz

  • Relative Humidity: 5–95% non-condensing

  • Configuration Port (CFG): RJ45 (DB-9M adapter supplied), RS-232 only

  • Communication Parameters:

    • Baud Rate: 110–115,200 baud

    • Stop Bits: 1 or 2

    • Data Size: 7 or 8 bits

    • Parity: None, Even, Odd

    • RTS Timing Delay: 0–65,535 ms

  • Modbus Modes: RTU (binary with CRC-16) and ASCII (with LRC error checking)

  • Floating Point Support: Enron, Daniel®, and other implementations supported

  • Shipping Weight: 2 kg

Core Features

  • Reduced data block design for optimized memory usage

  • Full support for Modbus RTU and ASCII communication modes

  • Configurable communication parameters for flexible integration

  • Floating point data handling with industry-standard implementations

  • Diagnostic LED indicators for monitoring module status

Application Scenarios

  • Integration of Modbus devices into ControlLogix systems with limited memory requirements

  • SCADA and distributed control systems requiring Modbus RTU or ASCII communication

  • Industrial automation setups needing configurable communication parameters

FAQ

  • Q: What distinguishes the MVI56-MCMR from the MVI56-MCM?  A: The MCMR version uses a reduced data block, making it suitable for applications with smaller memory requirements.

  • Q: Which Modbus modes are supported?  A: Both RTU (binary with CRC-16) and ASCII (with LRC error checking).

  • Q: Does the module support floating point data?  A: Yes, including Enron and Daniel-style implementations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more