Product Details

Product Overview

The Foxboro FBM204 P0914SY is a four-input, four-output isolated analog I/O module designed for precise process control in Foxboro I/A Series systems. It provides reliable 0–20 mA current loops for both sensing and control, with high accuracy and configurable signal processing.

Technical Specifications

 Manufacturer: Foxboro (Schneider Electric)
 Model Number: FBM204 P0914SY
 Input Channels: 4 isolated analog inputs
 Input Range: 0–20.4 mA DC nominal
 Input Accuracy: ±0.03% of span
 Temperature Coefficient: ±50 ppm/°C
 A/D Conversion: Independent Sigma-Delta per channel
 Input Impedance: 61.5 Ω nominal
 Integration Period: Software configurable
 Common Mode Rejection: >100 dB at 50/60 Hz
 Normal Mode Rejection: >95 dB at 50/60 Hz
 Maximum Field Device Distance: Dependent on compliance voltage, wire gauge, and voltage drop
 Output Channels: 4 isolated analog outputs
 Output Accuracy: ±0.03% of span
 Output Temperature Coefficient: ±50 ppm/°C
 Maximum Load: 750 Ω
 Processing Delay: 30 ms max
 Resolution: 13 bits

Key Features

• Four isolated input and output channels for high-precision signal control
• Independent Sigma-Delta conversion per input channel
• High common-mode and normal-mode rejection for signal integrity
• Configurable software integration period
• Compact and rugged design suitable for I/A Series DCS

Applications

• Chemical process monitoring and control
• Oil & gas instrumentation
• Power generation and energy management
• Any application requiring precise analog current control

FAQ

Q: What input signals does this module support?
A: 0–20.4 mA DC current loops.

Q: Are the channels isolated?
A: Yes, all input and output channels are galvanically isolated.

Q: What is the module’s resolution?
A: 13-bit resolution for output channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more