Only 10 left - Selling fast

PRODUCT SKU : MVI56-PDPS

PRODUCT TYPE : I/O Slave Network Interface

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MVI56-PDPS module from ProSoft Technology is a PROFIBUS DP I/O Slave interface designed for seamless integration with Allen Bradley ControlLogix systems. It enables reliable communication between ControlLogix controllers and PROFIBUS networks, supporting high-speed data transfer and robust industrial performance.

Key Specifications

  • Manufacturer: Allen Bradley / ProSoft Technology

  • Product Line: ControlLogix

  • Model: MVI56-PDPS

  • Part Number: MVI56-PDPS

  • Product Type: PROFIBUS DP I/O Slave Network Interface

  • Weight: 3.00 lbs (1.36 kg)

  • Slot(s): 1

  • Rack Type: Local or Remote

  • Data Transfer Type: Ladder Logic

  • Baud Rate: Up to 12 Mbps

  • PROFIBUS Node Address: Configurable from 0 to 125

  • Input Data Capacity: Maximum of 122 words

  • Shock Resistance: 30G operational rating

  • Backplane Current Load: 800 mA at 5V DC

Core Features

  • High-speed PROFIBUS DP communication up to 12 Mbps

  • Flexible node addressing for up to 126 devices

  • Ladder Logic integration for ControlLogix programming environments

  • Compact single-slot design suitable for local or remote racks

  • Industrial-grade durability with 30G shock resistance

Application Scenarios

  • Integration of PROFIBUS-based field devices into ControlLogix systems

  • Distributed control systems requiring PROFIBUS DP slave communication

  • Industrial automation setups needing reliable high-speed data exchange

FAQ

  • Q: What is the maximum baud rate supported by the MVI56-PDPS?  A: The module supports baud rates up to 12 Mbps.

  • Q: How many PROFIBUS nodes can be addressed?  A: Node addresses can be configured from 0 to 125, supporting up to 126 devices.

  • Q: Can this module be installed in remote racks?  A: Yes, it supports both local and remote rack configurations.

Comparison with Similar Modules

  • MVI56-MCM: Provides Modbus communication, suitable for Modbus networks.

  • MVI56-EIP: Designed for EtherNet/IP communication, ideal for Ethernet-based systems.

  • MVI56-GEC: Offers ASCII Ethernet communication, bridging legacy ASCII devices with ControlLogix.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more