Overview

The IC695ECM850 from GE Fanuc is a high-performance IEC 61850 Ethernet communication module designed for the PACSystems RX3i control family. It provides a standardized communication interface between GE RX3i controllers and intelligent electronic devices (IEDs), enabling interoperability in power generation, transmission, and industrial automation systems.

This module facilitates seamless integration of legacy Genius I/O networks and modern PROFINET environments, supporting reliable data exchange, time-synchronized control, and real-time system monitoring.

Technical Specifications

  • Model: IC695ECM850

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Product Type: IEC 61850 Ethernet Communication Module

  • Supported Protocols: IEC 61850, PROFINET v2.3 Class A, Modbus TCP/IP

  • Ethernet Ports: 2 × RJ-45 (10/100 Mbps), 2 × SFP cages for fiber optics

  • Additional Interfaces: 1 × Micro USB, SD card slot (for firmware upgrade and configuration storage)

  • Bus Type: RX3i Universal PCI backplane

  • I/O Update Rate: Configurable from 100 ms to 64 s

  • Maximum I/O Memory: 12,072 points and 20,000 events

  • Supported Devices: Up to 32 IEC 61850 IEDs

  • Power Requirements:

    • 24 VDC ±10% (0.5 A typical)

    • 3.3 VDC up to 1.5 A (5V with SFP modules)

  • Isolation: 1500 VAC between network and system backplane

  • Operating Temperature: 0°C to +60°C (32°F to 140°F)

  • Physical Dimensions: 13 × 16 × 2 cm

  • Weight: 1.0 lbs (0.45 kg)

  • Mounting: RX3i Universal Backplane

Applications

  • Substation automation and utility network communication

  • Integration of IEC 61850 IEDs into PACSystems RX3i control architectures

  • Industrial Ethernet communication and data acquisition systems

  • Power grid, energy management, and process control networks

FAQ

  • Q: What protocols are supported by the IC695ECM850?
    A: It supports IEC 61850, PROFINET v2.3 Class A, and Modbus TCP/IP.

  • Q: Can the module interface with fiber networks?
    A: Yes, it includes dual SFP cages for optical fiber connectivity.

  • Q: What is the maximum number of supported IEDs?
    A: The module can handle up to 32 IEC 61850 devices simultaneously.

  • Q: Does it support event buffering?
    A: Yes, it stores up to 20,000 events for efficient communication management.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more