Skip to content

What are you looking for?


You may also like

Honeywell Series 8 8C-PDISA1 SOE Digital Input ModuleHoneywell Series 8 8C-PDISA1 SOE Digital Input ModuleHoneywell Series 8 8C-PDISA1 SOE Digital Input Module
Honeywell Series 8 8C-PDISA1 SOE Digital Input Module
Honeywell Series 8 8C-PDISA1 SOE Digital Input Module
Honeywell Series 8 8C-PDISA1 SOE Digital Input Module

Honeywell Series 8 8C-PDISA1 SOE Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : 8C-PDISA1

PRODUCT TYPE : Digital Input Sequence Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The Honeywell 8C-PDISA1 module is designed to capture discrete 24 VDC signals with high precision timing for Sequence of Events (SOE) recording. It offers flexible operation modes, robust diagnostics, and enhanced reliability, making it ideal for critical industrial and process control applications.

Key Features:

  • Operation Modes: Normal (20 ms PV scan), SOE (1 ms resolution, 20 ms PV scan), Low Latency (5 ms PV scan)

  • Diagnostics: Advanced internal diagnostics for data integrity

  • Redundancy: Optional redundancy for improved reliability

  • Power Source: Supports internal or external field power sources

  • Excitation Power: Onboard excitation power eliminates need for external marshalling

  • Input Indication: Direct/Reverse input indication for clear signal status

  • Isolation: Galvanic isolation ensures safety and signal integrity

Technical Specifications:

  • Model Number: 8C-PDISA1

  • Module Type: Digital Input Sequence of Events, Coated

  • Input Channels: 32 discrete inputs

  • Input Scan Rate: Normal: 20 ms, Fast: 5 ms

  • SOE Digital Resolution: 1 ms

  • Voltage Rating: 24 VDC

  • Input Power Range: 18–30 VDC

  • Module Current: 95 mA

  • Galvanic Isolation: 1000 VAC RMS / ±1000 VDC, optical isolation

  • ON Sense Voltage/Current: ≥13 VDC / ≥3 mA

  • OFF Sense Voltage/Current: ≤5 VDC / ≤1.2 mA

  • Input Impedance: 4.2 kΩ

  • Absolute Delay: 5 ms ±20%

  • Field Resistance (ON): ≤300 Ω @ 15 VDC

  • Field Resistance (OFF): ≥30 kΩ @ 30 VDC

  • Hot Swap Capability: Module can be inserted or removed under power

Compatible Modules:

  • 8C-TDILA1: Non-redundant, Coated, 9"

  • 8C-TDILB1: Redundant, Coated, 12"

Applications:

  • Process Monitoring: Sequence of Events recording in process control

  • Automation: Monitoring and automation of critical field devices

  • Diagnostics: Power system and industrial plant diagnostics

FAQ:

  • Q: What is the minimum resolution for SOE?
    A: The module supports 1 ms digital resolution for accurate event timing.

  • Q: Can it operate with external field power?
    A: Yes, it can use either internal or external power sources.

  • Q: Is it safe for harsh industrial environments?
    A: Yes, galvanic isolation and robust diagnostics ensure safe, reliable operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more