Honeywell 8U-PWSP01-CN Series 8 Power Supply ModuleHoneywell 8U-PWSP01-CN Series 8 Power Supply ModuleHoneywell 8U-PWSP01-CN Series 8 Power Supply Module
Honeywell 8U-PWSP01-CN Series 8 Power Supply Module
Honeywell 8U-PWSP01-CN Series 8 Power Supply Module
Honeywell 8U-PWSP01-CN Series 8 Power Supply Module

Honeywell 8U-PWSP01-CN Series 8 Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : 8U-PWSP01-CN

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 8U-PWSP01-CN, also cataloged as the 8U-PWSP01-CN Power Supply Module, operates as a dedicated hardware component for regulated system bus voltage delivery within Honeywell Experion PKS Series 8 platforms.

Hardware Specifications

Parameter Specification
Model 8U-PWSP01-CN
Brand Honeywell
Origin USA
Weight 0.4 kg
Dimensions 7 cm x 14 cm x 14.5 cm
Operating Temp -25 deg C to +70 deg C
Power Consumption 100-240 VAC / VDC input
Output Voltage 24 VDC
Output Current 20 A
Voltage Regulation +/-0.5%
Isolation 2000 VAC
Redundancy Supported
Thermal Monitoring Six internal temperature sensors

Galvanic Isolation & Voltage Regulation Profiles

The module converts wide-range AC or DC input power into a tightly regulated 24 VDC power rail delivering up to 20 A to backplane I/O channels. Internal galvanic isolation rated at 2000 VAC prevents line transients and noise from coupling onto the internal DC distribution bus. Integrated circuitry maintains output regulation within +/-0.5% across dynamic load steps. Six internal thermal sensors continuously monitor operating states, providing contact signaling and status indication to protect against over-temperature events.

Frequently Asked Questions

Q: Does the 8U-PWSP01-CN support redundant power configurations on the Series 8 rack carrier?

A: Yes, the module supports redundant parallel operation to allow uninterrupted 24 VDC system power delivery during a single supply failure.

Q: What input power sources are compatible with the primary terminals?

A: The internal switching power circuit accepts an input range of 100-240 VAC or VDC.

Q: What isolation level exists between input power and system ground?

A: The hardware architecture provides 2000 VAC galvanic isolation between input power terminals and the internal control logic circuits.

Field Installation Guidelines

  1. Ensure the AC/DC main line circuit breaker is de-energized prior to seating or unseating the 8U-PWSP01-CN power module in the Series 8 rack slot.
  2. Verify that input line, neutral/DC potential, and protective earth (PE) wires are fully secured to terminal connections before applying power.
  3. Establish a direct low-impedance ground connection from the rack chassis grounding stud to the main enclosure ground bar.
  4. Maintain proper vertical clearance above and below the module chassis to allow natural air circulation across the heat sink surfaces.
  5. Confirm that total continuous 24 VDC load currents do not exceed the 20 A maximum rating under peak ambient operating conditions up to +70 deg C.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more