Product Details

Overview

The HIMA F2 DO 16 02/F2DO1602 is a safety-related remote output module engineered for high availability and robust performance in critical industrial automation systems. It is part of the HIMatrix F2 series and provides reliable SIL 3 performance for diverse safety applications. Designed for compact installation, this module supports streamlined communication and easy integration into existing control networks.

Technical Specifications

  • Manufacturer: HIMA

  • Model Number: F2 DO 16 02/F2DO1602

  • Product Type: Safety Controller Remote Output Module

  • Safety Integrity Level (SIL): 3

  • Number of Digital Inputs: 16

  • Number of Digital Outputs: 16

  • Communication Protocol: Modbus TCP/IP

  • Mounting: DIN rail

  • Dimensions (L × W × H): 25.3 × 11.6 × 10 cm

  • Weight: 2 kg

  • Key Features: Compact form factor, high availability, and wide safety application coverage

Key Features

  • Certified SIL 3 for maximum safety compliance

  • Supports 16 digital inputs and 16 digital outputs

  • Modbus TCP/IP communication for network integration

  • Compact DIN rail mounting for flexible installation

  • Designed for high reliability and continuous operation

Application Scenarios

The HIMA F2 DO 16 02 is suitable for:

  • Safety interlock and emergency shutdown systems

  • Process automation requiring remote output monitoring

  • Integration into HIMatrix F2 series safety networks

  • Industrial facilities demanding high system uptime and reliability

FAQ

Q: What safety standard does the F2DO1602 meet?
A: The module is SIL 3 certified, ensuring compliance with IEC 61508 safety standards.

Q: Can it communicate with existing Modbus networks?
A: Yes. The F2DO1602 supports Modbus TCP/IP for seamless integration into existing networks.

Q: What installation options are available?
A: It is designed for DIN rail mounting in standard control panels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more