PRODUCT SKU : X-FTA00201

PRODUCT TYPE : Field Termination Assembly

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The HIMA X-FTA 002 01 is a universal field termination assembly designed for direct connection between field devices and I/O modules in the HIMax safety control platform. It ensures reliable signal interfacing for both sensors and actuators, simplifying wiring in complex automation systems.

Built for durability and accuracy, this module includes shield connection terminals and mechanical coding to prevent incorrect cable mating. Available in both left-plug (X-FTA 002 01L) and right-plug (X-FTA 002 01R) configurations, it supports multiple I/O module types within HIMax architectures. The compact design allows easy DIN-rail mounting inside control cabinets, ensuring organized and service-friendly installations.

Technical Specifications

  • Manufacturer: HIMA Paul Hildebrandt GmbH + Co KG, Germany

  • Model: X-FTA 002 01

  • Part Numbers: 98 5030015 (01L), 98 5030023 (01R)

  • Product Type: Field Termination Assembly

  • Compatible I/O Modules:
    X-AI 32 01, X-AI 32 02 SOE, X-AO 16 01, X-CI 24 01, X-DI 32 01–05, X-DO 24 01/02, X-DO 32 01

  • Operating Voltage: 24 V DC

  • Ambient Temperature: 0°C to +60°C

  • Storage Temperature: –40°C to +85°C

  • Protection Class: III (IEC/EN 61131-2)

  • Pollution Degree: II

  • Installation Altitude: Up to 2000 m

  • Mounting: Standard DIN-rail installation

  • Shield Connection: Integrated terminal block

  • Mechanical Coding: Prevents incorrect cable connection

Features

  • Universal Compatibility: Interfaces with a wide range of HIMax analog and digital I/O modules.

  • Mechanical Keying: Prevents incorrect connection during installation.

  • Shield Support: Built-in grounding terminal for EMI protection.

  • DIN-Rail Mounting: Streamlined setup within safety system cabinets.

  • Robust Design: Withstands industrial operating conditions for long-term reliability.

  • Compact Construction: Saves space while maintaining high wiring density.

Applications

  • HIMax safety systems in process automation

  • Oil & gas, power generation, and chemical plant safety networks

  • Industrial control panels requiring modular field wiring

  • Safety instrumented systems using analog or digital field devices

FAQ

Q1: What is the function of the X-FTA 002 01 in a HIMax system?
A1: It connects field devices such as sensors and actuators to HIMax I/O modules for signal transmission.

Q2: Does this assembly support both analog and digital I/O?
A2: Yes, it is compatible with multiple analog and digital module types.

Q3: How can I ensure correct cable connection?
A3: The assembly includes a mechanical coding feature that prevents misconnection.

Q4: Where can it be installed?
A4: It mounts directly on standard DIN rails within control cabinets.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more