PRODUCT SKU : CC-PAONO1

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Honeywell CC-PAONO1 is a high-level analog output (AO) module engineered for precise control in process automation systems. Designed for integration with Honeywell distributed control systems, it delivers accurate 4–20 mA output signals and supports both non-redundant and redundant IOTA configurations. Its robust architecture ensures reliable performance for critical industrial applications.

Key Features

  • Provides 16 analog output channels with configurable ranges

  • Supports high-accuracy output with ±0.35% full-scale calibrated precision at 25°C

  • Low output ripple (<100 mV peak-to-peak) ensures stable signals

  • Redundant IOTA option allows seamless switchover within ≤10 ms

  • High-resolution output (±0.05% of full scale) and excellent linearity

  • Response time under 80 ms for fast control loop performance

  • Supports resistive loads up to 800 Ω with 24 VDC supply

Technical Specifications

  • Model Number: CC-PAONO1

  • Product Type: Analog Output (AO) Module – High-Level

  • IOTA Variants: Non-Redundant (CC-TAON01, 6"), Redundant (CC-TAON11, 12")

  • Output Type: 4–20 mA

  • Output Channels: 16

  • Output Ripple: <100 mV peak-to-peak at 250 Ω load

  • Output Temperature Drift: 0.005% of full scale per °C

  • Output Readback Accuracy: ±4% of full scale

  • Output Current Linearity: ±0.05% of full scale nominal

  • Resolution: ±0.05% of full scale

  • Calibrated Accuracy: ±0.35% of full scale at 25°C

  • Settable Output Range: 0–21.1 mA

  • Maximum Resistive Load: 800 Ω (with 24 V supply at 22–28 VDC)

  • Maximum Output Compliant Voltage: 16 V

  • Maximum Open Circuit Voltage: 22 V

  • Response Time: <80 ms to settle within 1% of final value

  • Switchover Gap (Redundant Mode): ≤10 ms for 0 mA output

Application Scenarios

The CC-PAONO1 is ideal for:

  • High-precision control loops in process automation

  • Critical applications requiring redundant analog output for reliability

  • Integration with Honeywell C300 or Experion control systems

  • Industries like oil & gas, chemical processing, and power generation

FAQ

Q: How many output channels does the CC-PAONO1 provide?
A: The module offers 16 analog output channels.

Q: What is the switchover time for the redundant IOTA version?
A: The redundant module switches over in ≤10 ms.

Q: What is the output range?
A: The module supports 0 mA to 21.1 mA, configurable for application needs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more